D1005UK

TT Electronics / Semelab D1005UK

Part No:

D1005UK

Package:

DM

ROHS:

AINNX NO:

23162009-D1005UK

Description:

Trans RF MOSFET N-CH 70V 20A 4-Pin Case DM

Products specifications
  • Package / Case
    DM
  • Material
    Si
  • ECCN (US)
    EAR99
  • Channel Mode
    Enhancement
  • Number of Elements per Chip
    1
  • Process Technology
    DMOS
  • Maximum Drain Source Voltage (V)
    70
  • Maximum Gate Source Voltage (V)
    ±20
  • Maximum VSWR
    20(Min)
  • Maximum Continuous Drain Current (A)
    20
  • Typical Input Capacitance @ Vds (pF)
    240(Max)@0V
  • Typical Reverse Transfer Capacitance @ Vds (pF)
    10(Max)@28V
  • Typical Output Capacitance @ Vds (pF)
    100(Max)@28V
  • Typical Forward Transconductance (S)
    3.2(Min)
  • Maximum Power Dissipation (mW)
    146000
  • Output Power (W)
    80
  • Typical Power Gain (dB)
    16(Min)
  • Maximum Frequency (MHz)
    175
  • Minimum Frequency (MHz)
    1
  • Typical Drain Efficiency (%)
    50(Min)
  • Minimum Operating Temperature (°C)
    -65
  • Maximum Operating Temperature (°C)
    200
  • AEC Qualified
    No
  • Supplier Package
    Case DM
  • Military
    No
  • Mounting
    Screw
  • Package Height
    6.6
  • Package Length
    24.76
  • Package Width
    12.7
  • PCB changed
    4
  • Vds - Drain-Source Breakdown Voltage
    70 V
  • Transistor Polarity
    N-Channel
  • Maximum Operating Temperature

    the maximum body temperature at which the thermistor is designed to operate for extended periods of time with acceptable stability of its electrical characteristics.

    + 150 C
  • Mounting Styles
    SMD/SMT
  • Id - Continuous Drain Current
    20 A
  • Part Status

    Parts can have many statuses as they progress through the configuration, analysis, review, and approval stages.

    Active
  • Technology
    Si
  • Pin Count

    a count of all of the component leads (or pins)

    4
  • Operating Frequency

    Operating frequency is the frequency at which the communications are being made with the total bandwidth occupied by the carrier signal with modulation. Usually bandwidth of the antenna will be wider than the bandwidth of the signal so that more than one center frequency the antenna can be put in to effective use.

    175 MHz
  • Configuration
    Single Dual Source
  • Output Power

    That power available at a specified output of a device under specified conditions of operation.

    80 W
  • Gain
    16 dB
  • Channel Type
    N
  • RoHS Status

    RoHS means “Restriction of Certain Hazardous Substances” in the “Hazardous Substances Directive” in electrical and electronic equipment.

    RoHS Compliant
0 Similar Products Remaining