3RT20181AV610UA0

Siemens 3RT20181AV610UA0

Part No:

3RT20181AV610UA0

Manufacturer:

Siemens

Datasheet:

-

Package:

-

AINNX NO:

28567127-3RT20181AV610UA0

Description:

CONTACTOR. 5HP 460/575V.1NO. 480

Products specifications
  • Mounting Type
    Chassis Mount, DIN Rail
  • Mfr
    Siemens
  • Box
  • Product Status
    Active
  • Contact Materials
    -
  • CoilResistance
    -
  • Base Product Number
    3RT2018
  • Type of electrical connection of main circuit
    Screw connection
  • Number of auxiliary contacts as normally open contact
    1
  • Modular version
    Yes
  • Rated operation power NEMA
    3.677
  • Number of normally open contacts as main contact
    3
  • Rated control supply voltage at AC 60 Hz
    480 - 480
  • Rated operation current Ie at AC-4, 400 V
    11.5
  • Voltage type for actuating
    AC
  • Rated operation current Ie at AC-3, 400 V
    18
  • Rated operation power at AC-3, 400 V
    7.5
  • Rated operation current Ie at AC-1, 400 V
    22
  • Operating Temperature

    The operating temperature is the range of ambient temperature within which a power supply, or any other electrical equipment, operate in. This ranges from a minimum operating temperature, to a peak or maximum operating temperature, outside which, the power supply may fail.

    -25°C ~ 60°C
  • Termination Style
    Screw Terminal
  • Contact Form

    A page on a website that allows users to communicate with the site owner. The page has fields for filling in name, address and type of comment. On most company websites, email and mailing addresses are also included; however, the contact form provides an immediate, convenient way for users to ask the company questions.

    3PST-NO (3 Form A)
  • Operate Time

    The time interval between the instant of the occurrence of a specified input condition to a system and the instant of completion of a specified operation.

    35 ms
  • Coil Voltage
    480VAC
  • Switching Voltage

    The maximum switching voltage of a relay is the maximum voltage that can be across the contacts whether the relay is open or closed. Operating a relay with high voltages present can cause arcing, and this in turn erodes the contacts and eventually degrades contact performance.

    690VAC - Max
  • Release Time

    In telecommunication, release time is the time interval for a circuit to respond when an enabling signal is discontinued

    13 ms
  • Must Operate Voltage
    408 VAC
  • Contact Rating (Current)
    10 A
  • Coil Power
    43VA
  • Must Release Voltage
    -
  • Features
    Auxiliary Contacts
0 Similar Products Remaining