Mounting Type
Chassis Mount, DIN Rail
Mfr
Siemens
Package
Bulk
Product Status
Active
Contact Materials
-
CoilResistance
-
Base Product Number
3RT1066
Dim
(W x H x D) 145 x 210 x 202 mm
RoHS-compliant
Yes
Connections
Terminal strip
No. of pins
3-pin
Number of auxiliary contacts as normally open contact
2
Nominal voltage
1000V AC
Number of normally open contacts as main contact
3
Rated operation current Ie at AC-4, 400 V
280A
Min. temperature
-25°C
Rated operation current Ie at AC-3, 400 V
300A
Content
1pc(s)
Max. temperature
+60°C
Rated operation power at AC-3, 400 V
160kW
Rated operation power at AC-4, 400 V
160kW
Rated operation current Ie at AC-1, 400 V
330A
Number of auxiliary contacts as normally closed contact
2
Manufacturer Part Number
3RT10666AF36
Manufacturer
Siemens Building Technologies
Range
SIRIUS
Rated control supply voltage at AC 50 Hz
110 - 127
Type of electrical connection of main circuit
Rail connection
Modular version
Yes
Rated operation power NEMA
183.875
Rated control supply voltage at AC 60 Hz
110 - 127
Voltage type for actuating
AC/DC
Number of normally closed contacts as main contact
0
Rated control supply voltage at DC
110 - 127
Series
3RT1
Operating Temperature
The operating temperature is the range of ambient temperature within which a power supply, or any other electrical equipment, operate in. This ranges from a minimum operating temperature, to a peak or maximum operating temperature, outside which, the power supply may fail.
-25°C ~ 60°C
Type
S10
Power Rating
160 kW
Depth
202mm
Termination Style
Screw Terminal
Durability
1000 0000
Number of Poles
3
Contact Current Rating
The current rating of a contact is defined as the current level that creates a certain temperature rise of the contact spring — usually 20°C or 30°C. Both electrical and thermal factors govern the heat created by the current.
300 A
Contact Form
A page on a website that allows users to communicate with the site owner. The page has fields for filling in name, address and type of comment. On most company websites, email and mailing addresses are also included; however, the contact form provides an immediate, convenient way for users to ask the company questions.
3PST-NO (3 Form A)
Operate Time
The time interval between the instant of the occurrence of a specified input condition to a system and the instant of completion of a specified operation.
95 ms
Coil Voltage
110 ~ 127VAC/DC
Switching Voltage
The maximum switching voltage of a relay is the maximum voltage that can be across the contacts whether the relay is open or closed. Operating a relay with high voltages present can cause arcing, and this in turn erodes the contacts and eventually degrades contact performance.
1000VAC - Max
Release Time
In telecommunication, release time is the time interval for a circuit to respond when an enabling signal is discontinued
80 ms
Must Operate Voltage
-
Contact Rating (Current)
300 A
Coil Power
650W
Must Release Voltage
-
Features
Auxiliary Contacts
Width
145mm
Height
210mm