3RT25162AP00

Siemens 3RT25162AP00

Part No:

3RT25162AP00

Manufacturer:

Siemens

Datasheet:

-

Package:

-

AINNX NO:

28528074-3RT25162AP00

Description:

CONTACTOR S00 9A 230VAC 2NO/2NC

Products specifications
  • Mounting Type
    Chassis Mount, DIN Rail
  • Mfr
    Siemens
  • Package
    Box
  • Product Status
    Active
  • Contact Materials
    -
  • CoilResistance
    -
  • Base Product Number
    3RT2516
  • Dim
    (W x H x D) 45 x 70 x 73 mm
  • RoHS-compliant
    Yes
  • No. of pins
    4-pin
  • Number of auxiliary contacts as normally open contact
    0
  • Number of normally open contacts as main contact
    2
  • Min. temperature
    -25°C
  • Rated operation current Ie at AC-3, 400 V
    9A
  • Content
    1pc(s)
  • Max. temperature
    +60°C
  • Number of normally closed contacts as main contact
    2
  • Rated operation power at AC-3, 400 V
    4kW
  • Rated operation current Ie at AC-1, 400 V
    18A
  • Number of auxiliary contacts as normally closed contact
    0
  • Type of electrical connection of main circuit
    Spring clamp connection
  • Modular version
    Yes
  • Rated operation power NEMA
    3.677
  • Voltage type for actuating
    AC
  • Series
    SIRIUS
  • Operating Temperature

    The operating temperature is the range of ambient temperature within which a power supply, or any other electrical equipment, operate in. This ranges from a minimum operating temperature, to a peak or maximum operating temperature, outside which, the power supply may fail.

    -25°C ~ 60°C
  • Type
    S00
  • Depth
    73mm
  • Termination Style
    Spring Terminal
  • Durability
    3000 0000
  • Contact Form

    A page on a website that allows users to communicate with the site owner. The page has fields for filling in name, address and type of comment. On most company websites, email and mailing addresses are also included; however, the contact form provides an immediate, convenient way for users to ask the company questions.

    4PST-2NO/2NC (2 Form A, 2 Form B)
  • Operate Time

    The time interval between the instant of the occurrence of a specified input condition to a system and the instant of completion of a specified operation.

    35 ms
  • Coil Voltage
    230VAC
  • Switching Voltage

    The maximum switching voltage of a relay is the maximum voltage that can be across the contacts whether the relay is open or closed. Operating a relay with high voltages present can cause arcing, and this in turn erodes the contacts and eventually degrades contact performance.

    690VAC - Max
  • Release Time

    In telecommunication, release time is the time interval for a circuit to respond when an enabling signal is discontinued

    13 ms
  • Must Operate Voltage
    184 VAC
  • Contact Rating (Current)
    9 A
  • Coil Power
    27VA
  • Must Release Voltage
    -
  • Features
    Auxiliary Contacts
  • Width
    45mm
  • Height
    70mm