3RH21402GG20

Siemens 3RH21402GG20

Part No:

3RH21402GG20

Manufacturer:

Siemens

Datasheet:

-

Package:

-

AINNX NO:

28571584-3RH21402GG20

Description:

CONTACTOR RELAY 4NO AC 110V SPRI

Products specifications
  • Mounting Type
    Chassis Mount, DIN Rail
  • Mfr
    Siemens
  • Box
  • Product Status
    Active
  • Contact Materials
    -
  • CoilResistance
    -
  • Base Product Number
    3RH21402
  • Dim
    (W x H x D) 45 x 70 x 73 mm
  • RoHS-compliant
    Yes
  • Number of auxiliary contacts as normally open contact
    4
  • Min. temperature
    -25°C
  • Content
    1pc(s)
  • Max. temperature
    +60°C
  • Auxiliary contact type
    4 makers
  • Rated control supply voltage at AC 50 Hz
    110 - 110
  • Rated control supply voltage at AC 60 Hz
    110 - 110
  • Voltage type for actuating
    AC
  • Rated control supply voltage at DC
    100 - 100
  • Number of auxiliary contacts as normally closed contact
    0
  • Operating Temperature

    The operating temperature is the range of ambient temperature within which a power supply, or any other electrical equipment, operate in. This ranges from a minimum operating temperature, to a peak or maximum operating temperature, outside which, the power supply may fail.

    -25°C ~ 60°C
  • Type
    S00
  • Depth
    73mm
  • Termination Style
    Spring Terminal
  • Interface
    No
  • Durability
    3000 0000
  • Contact Form

    A page on a website that allows users to communicate with the site owner. The page has fields for filling in name, address and type of comment. On most company websites, email and mailing addresses are also included; however, the contact form provides an immediate, convenient way for users to ask the company questions.

    4PST-NO (4 Form A)
  • Operate Time

    The time interval between the instant of the occurrence of a specified input condition to a system and the instant of completion of a specified operation.

    100 ms
  • Coil Voltage
    110VAC
  • Switching Voltage

    The maximum switching voltage of a relay is the maximum voltage that can be across the contacts whether the relay is open or closed. Operating a relay with high voltages present can cause arcing, and this in turn erodes the contacts and eventually degrades contact performance.

    690VAC - Max
  • Release Time

    In telecommunication, release time is the time interval for a circuit to respond when an enabling signal is discontinued

    65 ms
  • Must Operate Voltage
    93.5 VAC
  • Contact Rating (Current)
    10 A
  • Coil Power
    5.7VA
  • Must Release Voltage
    -
  • Features
    Auxiliary Contacts
  • Width
    45mm
  • Height
    70mm
0 Similar Products Remaining