XU2M18MA230K

Schneider Electric XU2M18MA230K

Part No:

XU2M18MA230K

Manufacturer:

Schneider Electric

Datasheet:

-

Package:

-

AINNX NO:

28789410-XU2M18MA230K

Description:

PHOTOELECTRIC SENSORS XU

Products specifications
  • Mfr
    Schneider Electric
  • Product Status
    Active
  • Package
    Box
  • Explosion safety category for dust
    None
  • Rated control supply voltage at DC
    24 - 240
  • Explosion safety category for gas
    None
  • Suitable for safety functions
    No
  • Degree of protection (IP)
    IP67K
  • Voltage type
    AC/DC
  • Material housing
    Metal
  • Max. output current
    200
  • Rated control supply voltage at AC 60 Hz
    24 - 240
  • Ambient temperature
    -25 - 55
  • Type of electric connection
    Connector 1/2 inch
  • Rated control supply voltage at AC 50 Hz
    24 - 240
  • Series
    -
  • Operating Temperature

    The operating temperature is the range of ambient temperature within which a power supply, or any other electrical equipment, operate in. This ranges from a minimum operating temperature, to a peak or maximum operating temperature, outside which, the power supply may fail.

    -25°C ~ 55°C
  • Voltage - Supply
    24 ~ 240VAC/DC
  • Ingress Protection

    Ingress Protection rating (or just IP rating), is an international standard (IEC 60529) used to rate the degree of protection or sealing effectiveness in electrical enclosures against intrusion of objects, water, dust or accidental contact. It corresponds to the European standard EN 60529.

    IP67
  • Output Configuration
    SCR, NO
  • Cable Length

    A nautical unit of measure equal to one tenth of a nautical mile or approximately 1 fathoms.

    -
  • Response Time

    the time taken for a circuit or measuring device, when subjected to a change in input signal, to change its state by a specified fraction of its total response to that change.

    20ms
  • Adjustment Type
    Adjustable
  • Sensing Distance

    It is the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation. (Normally, it is 70 to 80 % of the maximum operation distance.)

    590.551" (15m)
  • Sensing Method
    Through-Beam
  • Connection Method

    the systematic way of connecting the Power Plant (units) to the power grid.

    Connector, UNF
  • Light Source

    an optical transmitter that is paired with an optical receiver, both of which are connected to electrically based devices or systems.

    Red LED, Yellow LED
0 Similar Products Remaining