XU2N18KP9AAL5T

Schneider Electric XU2N18KP9AAL5T

Part No:

XU2N18KP9AAL5T

Manufacturer:

Schneider Electric

Datasheet:

-

Package:

-

AINNX NO:

28670600-XU2N18KP9AAL5T

Description:

PHOTOELECTRIC SENSORS XU, XU2, T

Products specifications
  • Housing Material
    Metal
  • Mfr
    Schneider Electric
  • Package
    Box
  • Product Status
    Active
  • Rated control supply voltage at AC 50 Hz
    24 - 240
  • Type of electric connection
    Cable radial
  • Ambient temperature
    -25 - 55
  • Rated control supply voltage at AC 60 Hz
    24 - 240
  • Max. output current
    100
  • Material housing
    Metal
  • Voltage type
    AC/DC
  • Degree of protection (IP)
    IP67K
  • Suitable for safety functions
    No
  • Explosion safety category for gas
    None
  • Explosion safety category for dust
    None
  • RoHS
    Non-Compliant
  • Series
    -
  • Operating Temperature

    The operating temperature is the range of ambient temperature within which a power supply, or any other electrical equipment, operate in. This ranges from a minimum operating temperature, to a peak or maximum operating temperature, outside which, the power supply may fail.

    -25°C ~ 55°C
  • Voltage - Supply
    24 ~ 240VAC/DC
  • Ingress Protection

    Ingress Protection rating (or just IP rating), is an international standard (IEC 60529) used to rate the degree of protection or sealing effectiveness in electrical enclosures against intrusion of objects, water, dust or accidental contact. It corresponds to the European standard EN 60529.

    IP67
  • Output Configuration
    NC/NO
  • Cable Length

    A nautical unit of measure equal to one tenth of a nautical mile or approximately 1 fathoms.

    984.25" (25m)
  • Response Time

    the time taken for a circuit or measuring device, when subjected to a change in input signal, to change its state by a specified fraction of its total response to that change.

    1ms
  • Adjustment Type
    -
  • Sensing Distance

    It is the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation. (Normally, it is 70 to 80 % of the maximum operation distance.)

    590.551" (15m)
  • Sensing Method
    Through-Beam
  • Connection Method

    the systematic way of connecting the Power Plant (units) to the power grid.

    Cable
  • Light Source

    an optical transmitter that is paired with an optical receiver, both of which are connected to electrically based devices or systems.

    -
0 Similar Products Remaining