XUBTANSNM12

Schneider XUBTANSNM12

Part No:

XUBTANSNM12

Manufacturer:

Schneider

Datasheet:

-

Package:

-

AINNX NO:

44235491-XUBTANSNM12

Description:

PHOTOELECTRIC SENSORS 18MM NPN X

Products specifications
  • Housing Material
    PBT
  • Package
    Box
  • Mfr
    Schneider Electric
  • Product Status
    Active
  • Type of electric connection
    Connector M12
  • Ambient temperature
    0 - 55
  • Max. output current
    100
  • Material housing
    Plastic
  • Voltage type
    AC/DC
  • Degree of protection (IP)
    IP67K
  • Suitable for safety functions
    No
  • Explosion safety category for gas
    None
  • Rated control supply voltage at DC
    12 - 24
  • Explosion safety category for dust
    None
  • RoHS
    Compliant
  • Operating Temperature

    The operating temperature is the range of ambient temperature within which a power supply, or any other electrical equipment, operate in. This ranges from a minimum operating temperature, to a peak or maximum operating temperature, outside which, the power supply may fail.

    0°C ~ 55°C
  • Series
    XU
  • Max Operating Temperature

    The Maximum Operating Temperature is the maximum body temperature at which the thermistor is designed to operate for extended periods of time with acceptable stability of its electrical characteristics.

    55 °C
  • Min Operating Temperature
    0 °C
  • Voltage - Supply
    12V ~ 24V
  • Ingress Protection

    Ingress Protection rating (or just IP rating), is an international standard (IEC 60529) used to rate the degree of protection or sealing effectiveness in electrical enclosures against intrusion of objects, water, dust or accidental contact. It corresponds to the European standard EN 60529.

    IP65
  • Output Configuration
    NPN-NC/NO
  • Cable Length

    A nautical unit of measure equal to one tenth of a nautical mile or approximately 1 fathoms.

    -
  • Response Time

    the time taken for a circuit or measuring device, when subjected to a change in input signal, to change its state by a specified fraction of its total response to that change.

    -
  • Adjustment Type
    -
  • Sensing Distance

    It is the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation. (Normally, it is 70 to 80 % of the maximum operation distance.)

    0.709 (18mm)
  • Sensing Method
    Reflective
  • Connection Method

    the systematic way of connecting the Power Plant (units) to the power grid.

    Connector, M12
  • Light Source

    an optical transmitter that is paired with an optical receiver, both of which are connected to electrically based devices or systems.

    Red LED
  • Ratings
    IP65
0 Similar Products Remaining