380D45

Opto 22 380D45

Part No:

380D45

Manufacturer:

Opto 22

Package:

120

ROHS:

AINNX NO:

21317025-380D45

Description:

Relay, 45 A, 380 VAC, Solid State, 120, 0.9 W, Panel, 2.25 in. L x 1.75 in. W

Products specifications
  • Package / Case
    120
  • Mount
    Panel, Screw
  • Number of Pins
    4
  • Voltage Rating (AC)
    380 V
  • Input Polarity
    AC
  • Manufacturer Part Number
    380D45
  • Manufacturer
    Opto 22
  • Mounting
    Panel
  • Operating Temperature Classification
    Industrial
  • Output Device
    SCR
  • Operating Temp Range
    -40C to 100C
  • Output Voltage (Max)
    380(V)
  • Rad Hardened
    No
  • Approvals
    CE, CSA, UL
  • RoHS
    Compliant
  • Operating Temperature-Min
    -40 °C
  • Operating Temperature-Max
    100 °C
  • Part Life Cycle Code
    Contact Manufacturer
  • Ihs Manufacturer
    OPTO TWENTY-TWO (22)
  • Risk Rank
    5.27
  • Termination
    Screw
  • Max Operating Temperature

    The Maximum Operating Temperature is the maximum body temperature at which the thermistor is designed to operate for extended periods of time with acceptable stability of its electrical characteristics.

    100 °C
  • Min Operating Temperature
    -40 °C
  • HTS Code

    HTS (Harmonized Tariff Schedule) codes are product classification codes between 8-1 digits. The first six digits are an HS code, and the countries of import assign the subsequent digits to provide additional classification. U.S. HTS codes are 1 digits and are administered by the U.S. International Trade Commission.

    8541.40.95.00
  • Capacitance
    8 pF
  • Subcategory
    Solid State Relays
  • Power Rating
    900 mW
  • Depth
    57.2 mm
  • Reach Compliance Code
    compliant
  • Current Rating

    Current rating is the maximum current that a fuse will carry for an indefinite period without too much deterioration of the fuse element.

    45 A
  • Pin Count

    a count of all of the component leads (or pins)

    4
  • Approval Agency
    CE, CSA, UL
  • Output Voltage
    3-32 VDC
  • Output Type
    AC
  • Operating Supply Voltage

    The voltage level by which an electrical system is designated and to which certain operating characteristics of the system are related.

    420 V
  • Number of Circuits
    1
  • Output Current

    The rated output current is the maximum load current that a power supply can provide at a specified ambient temperature. A power supply can never provide more current that it's rated output current unless there is a fault, such as short circuit at the load.

    45000(mA)
  • Throw Configuration
    SPST
  • Input Type
    AC
  • Max Output Voltage

    The maximum output voltage refers to the dynamic area beyond which the output is saturated in the positive or negative direction, and is limited according to the load resistance value.

    380 V
  • Overall Height
    22 mm
  • Nominal Output Voltage
    3.3 VDC, 6 VDC, 12 VDC, 24 VDC
  • Load Current

    The Load Current can be defined as 1) Full load current the maximum current that an electrical machine can operate; 2) Rated Current the current rated on the nameplate of an electrical machine; 3) Nominal Current is generally mentioned in the specification documents that is normally the same value as the rated one.

    45 A
  • Isolation Voltage

    Isolation voltage refers to a test of the ability of an insulator to minimize the flow of electric current with a high applied voltage.

    4000(V)
  • Max Supply Voltage (AC)
    420 V
  • Input Signal

    input signal is the signal going into an electronic system.

    24-420 VAC
  • Overall Length
    57 mm
  • Output Circuit Type
    Back to Back SCR
  • Control Voltage
    3 V
  • Min Supply Voltage (AC)
    24 V
  • Input Voltage
    420(V)
  • Height
    19.6 mm
  • Length
    44.5 mm
  • Width
    44.4 mm
  • RoHS Status

    RoHS means “Restriction of Certain Hazardous Substances” in the “Hazardous Substances Directive” in electrical and electronic equipment.

    RoHS Compliant