120D10

Opto 22 120D10

Part No:

120D10

Manufacturer:

Opto 22

Package:

Module

ROHS:

AINNX NO:

21316304-120D10

Description:

Relay, 10 A (Nom.), Solid State, 3 VDC (Pick-UP), 1 VDC (Drop-Out), Panel Mount

Products specifications
  • Package / Case
    Module
  • Mount
    Panel, Screw
  • Mounting Type
    Chassis Mount
  • Number of Pins
    4
  • Input Polarity
    AC
  • Manufacturer Part Number
    120D10
  • Manufacturer
    Opto 22
  • Mounting
    Panel
  • Switching Mode
    DC Switch
  • RoHS
    Compliant
  • Approvals
    CE, CSA, UL
  • Package
    Box
  • Mfr
    Opto 22
  • Product Status
    Active
  • Series
    -
  • Termination
    Screw
  • Resistance
    1 kΩ
  • Max Operating Temperature

    The Maximum Operating Temperature is the maximum body temperature at which the thermistor is designed to operate for extended periods of time with acceptable stability of its electrical characteristics.

    100 °C
  • Min Operating Temperature
    -40 °C
  • Depth
    24.5 mm
  • Current Rating

    Current rating is the maximum current that a fuse will carry for an indefinite period without too much deterioration of the fuse element.

    10 A
  • Termination Style
    Screw Terminal
  • Approval Agency
    CE, CSA, UL
  • Output Voltage
    140 V
  • Output Type
    AC, Zero Cross
  • Operating Supply Voltage

    The voltage level by which an electrical system is designated and to which certain operating characteristics of the system are related.

    140 V
  • Circuit
    SPST-NO (1 Form A)
  • Number of Circuits
    1
  • Max Voltage Rating (AC)
    140 V
  • Output Current

    The rated output current is the maximum load current that a power supply can provide at a specified ambient temperature. A power supply can never provide more current that it's rated output current unless there is a fault, such as short circuit at the load.

    10 A
  • Voltage - Load
    12 ~ 140V
  • Nominal Output Voltage
    3.3 VDC, 6 VDC, 12 VDC, 24 VDC
  • Input Current
    10 A
  • Load Current

    The Load Current can be defined as 1) Full load current the maximum current that an electrical machine can operate; 2) Rated Current the current rated on the nameplate of an electrical machine; 3) Nominal Current is generally mentioned in the specification documents that is normally the same value as the rated one.

    10 A
  • Max Supply Voltage (AC)
    140 V
  • Input Signal

    input signal is the signal going into an electronic system.

    12-140 VAC
  • Contact Configuration
    -
  • Min Supply Voltage (AC)
    12 V
  • Height
    23.6 mm
  • Length
    44.5 mm
  • Width
    57.2 mm
  • RoHS Status

    RoHS means “Restriction of Certain Hazardous Substances” in the “Hazardous Substances Directive” in electrical and electronic equipment.

    RoHS Compliant
  • Lead Free
    Lead Free
0 Similar Products Remaining