240D45

Opto 22 240D45

Part No:

240D45

Manufacturer:

Opto 22

Package:

Module

ROHS:

AINNX NO:

21317677-240D45

Description:

240 VAC, 45 Amp, DC Control Solid State Relay SSR

Products specifications
  • Package / Case
    Module
  • Mount
    Panel, Screw
  • Mounting Type
    Chassis Mount
  • Number of Pins
    4
  • Mounting
    Panel
  • Manufacturer
    Opto 22
  • Manufacturer Part Number
    240D45
  • Input Polarity
    AC
  • Switching Mode
    DC Switch
  • Package
    Box
  • Mfr
    Opto 22
  • Product Status
    Active
  • Operating Temperature-Min
    -40 °C
  • Operating Temperature-Max
    100 °C
  • Rohs Code
    Yes
  • Part Life Cycle Code
    Contact Manufacturer
  • Ihs Manufacturer
    OPTO TWENTY-TWO (22)
  • Risk Rank
    5.4
  • Series
    -
  • Termination
    Screw
  • Max Operating Temperature

    The Maximum Operating Temperature is the maximum body temperature at which the thermistor is designed to operate for extended periods of time with acceptable stability of its electrical characteristics.

    100 °C
  • Min Operating Temperature
    -40 °C
  • HTS Code

    HTS (Harmonized Tariff Schedule) codes are product classification codes between 8-1 digits. The first six digits are an HS code, and the countries of import assign the subsequent digits to provide additional classification. U.S. HTS codes are 1 digits and are administered by the U.S. International Trade Commission.

    8541.40.95.00
  • Subcategory
    Solid State Relays
  • Power Rating
    4 kW
  • Depth
    24.5 mm
  • Reach Compliance Code
    compliant
  • Current Rating

    Current rating is the maximum current that a fuse will carry for an indefinite period without too much deterioration of the fuse element.

    45 A
  • Termination Style
    Screw Terminal
  • Approval Agency
    CE, CSA, UL
  • Output Voltage
    280 V
  • Output Type
    AC, Zero Cross
  • Circuit
    SPST-NO (1 Form A)
  • Number of Circuits
    1
  • Max Voltage Rating (AC)
    280 V
  • Output Current

    The rated output current is the maximum load current that a power supply can provide at a specified ambient temperature. A power supply can never provide more current that it's rated output current unless there is a fault, such as short circuit at the load.

    45 A
  • Throw Configuration
    SPST
  • Input Type
    DC
  • Max Output Voltage

    The maximum output voltage refers to the dynamic area beyond which the output is saturated in the positive or negative direction, and is limited according to the load resistance value.

    240 V
  • Voltage - Load
    24 ~ 280V
  • Overall Height
    22 mm
  • Nominal Output Voltage
    3.3 VDC, 6 VDC, 12 VDC, 24 VDC
  • Input Current
    45 A
  • Load Current

    The Load Current can be defined as 1) Full load current the maximum current that an electrical machine can operate; 2) Rated Current the current rated on the nameplate of an electrical machine; 3) Nominal Current is generally mentioned in the specification documents that is normally the same value as the rated one.

    45 A
  • Max Supply Voltage (AC)
    280 V
  • Input Signal

    input signal is the signal going into an electronic system.

    24-280 VAC
  • Overall Length
    57 mm
  • Output Circuit Type
    Back to Back SCR
  • Control Voltage
    3 V
  • Contact Configuration
    SPST
  • Min Supply Voltage (AC)
    24 V
  • Length
    44.5 mm
  • Width
    57.2 mm
  • RoHS Status

    RoHS means “Restriction of Certain Hazardous Substances” in the “Hazardous Substances Directive” in electrical and electronic equipment.

    RoHS Compliant
  • Lead Free
    Lead Free
0 Similar Products Remaining