22.34.0.230.1320

Finder Relays, Inc. 22.34.0.230.1320

Part No:

22.34.0.230.1320

Manufacturer:

Finder Relays, Inc.

Datasheet:

-

Package:

-

AINNX NO:

28502900-22.34.0.230.1320

Description:

MODULAR CONTACTOR, 4PST-NO 25A,

Products specifications
  • Mounting Type
    DIN Rail
  • Mfr
    Finder Relays, Inc.
  • Package
    Box
  • Product Status
    Active
  • Contact Materials
    Silver Nickel (AgNi)
  • CoilResistance
    26.44kOhms
  • Rated control supply voltage at AC 50 Hz
    230 - 230
  • Type of electrical connection of main circuit
    Screw connection
  • Number of auxiliary contacts as normally open contact
    0
  • Modular version
    Yes
  • Number of normally open contacts as main contact
    4
  • Rated control supply voltage at AC 60 Hz
    230 - 230
  • Voltage type for actuating
    AC/DC
  • Rated operation current Ie at AC-3, 400 V
    10
  • Number of normally closed contacts as main contact
    0
  • Rated operation power at AC-3, 400 V
    4
  • Rated operation current Ie at AC-1, 400 V
    25
  • Rated control supply voltage at DC
    230 - 230
  • Number of auxiliary contacts as normally closed contact
    0
  • Series
    22
  • Operating Temperature

    The operating temperature is the range of ambient temperature within which a power supply, or any other electrical equipment, operate in. This ranges from a minimum operating temperature, to a peak or maximum operating temperature, outside which, the power supply may fail.

    -20°C ~ 50°C
  • Termination Style
    Screw Terminal
  • Contact Form

    A page on a website that allows users to communicate with the site owner. The page has fields for filling in name, address and type of comment. On most company websites, email and mailing addresses are also included; however, the contact form provides an immediate, convenient way for users to ask the company questions.

    4PST-NO (4 Form A)
  • Operate Time

    The time interval between the instant of the occurrence of a specified input condition to a system and the instant of completion of a specified operation.

    18 ms
  • Coil Voltage
    230VAC/DC
  • Switching Voltage

    The maximum switching voltage of a relay is the maximum voltage that can be across the contacts whether the relay is open or closed. Operating a relay with high voltages present can cause arcing, and this in turn erodes the contacts and eventually degrades contact performance.

    250VAC - Nom
  • Coil Current

    A current coil is basically a coil, such as, a wire wrapped around an electrical conductor.

    8.7 mA
  • Release Time

    In telecommunication, release time is the time interval for a circuit to respond when an enabling signal is discontinued

    40 ms
  • Must Operate Voltage
    184 VAC/DC
  • Contact Rating (Current)
    25 A
  • Coil Power
    2.2W
  • Must Release Voltage
    23 VAC/DC
  • Features
    Lighted Indicator, Mechanical Indicator
0 Similar Products Remaining