Mounting Type
DIN Rail
Mfr
Finder Relays, Inc.
Package
Box
Product Status
Active
Contact Materials
Silver Nickel (AgNi)
CoilResistance
7.27kOhms
Dim
(W x H x D) 35 x 84 x 60.8 mm
Connections
Screw terminal
Fall time
40ms
Nominal voltage
120V DC,120V AC
Ambient temperature
-20 - +50°C
Switching voltage (max.)
440V AC
Min. temperature
-20°C
Content
1pc(s)
Max. temperature
+50°C
Electrical lifespan
2 x 10<sup>6</sup> switching operations
Max. switching capacity
6250VA
Nominal current (details)
(AC-7b, AC-7c) 10A
Rated control supply voltage at AC 50 Hz
120 - 120
Type of electrical connection of main circuit
Screw connection
Number of auxiliary contacts as normally open contact
0
Modular version
Yes
Number of normally open contacts as main contact
2
Rated control supply voltage at AC 60 Hz
120 - 120
Voltage type for actuating
AC/DC
Rated operation current Ie at AC-3, 400 V
10
Number of normally closed contacts as main contact
2
Rated operation power at AC-3, 400 V
4
Rated operation current Ie at AC-1, 400 V
25
Rated control supply voltage at DC
120 - 120
Number of auxiliary contacts as normally closed contact
0
RoHS
Non-Compliant
Series
22
Operating Temperature
The operating temperature is the range of ambient temperature within which a power supply, or any other electrical equipment, operate in. This ranges from a minimum operating temperature, to a peak or maximum operating temperature, outside which, the power supply may fail.
-20°C ~ 50°C
Type
22.34.0.120.1620
Depth
60.8mm
Termination Style
Screw Terminal
Durability
30 x 10<sup>3</sup> switching operations
Contact Form
A page on a website that allows users to communicate with the site owner. The page has fields for filling in name, address and type of comment. On most company websites, email and mailing addresses are also included; however, the contact form provides an immediate, convenient way for users to ask the company questions.
4PST-2NO/2NC (2 Form A, 2 Form B)
Operate Time
The time interval between the instant of the occurrence of a specified input condition to a system and the instant of completion of a specified operation.
18 ms
Coil Voltage
120VAC/DC
Switching Voltage
The maximum switching voltage of a relay is the maximum voltage that can be across the contacts whether the relay is open or closed. Operating a relay with high voltages present can cause arcing, and this in turn erodes the contacts and eventually degrades contact performance.
250VAC - Nom
Coil Current
A current coil is basically a coil, such as, a wire wrapped around an electrical conductor.
16.5 mA
Release Time
In telecommunication, release time is the time interval for a circuit to respond when an enabling signal is discontinued
40 ms
Must Operate Voltage
88 VAC/DC
Contact Rating (Current)
25 A
Coil Power
2.2W
Must Release Voltage
12 VAC/DC
Features
Lighted Indicator, Mechanical Indicator
Width
35mm
Height
84mm
Ratings
IP20