22.34.0.024.1340

Finder Relays, Inc. 22.34.0.024.1340

Part No:

22.34.0.024.1340

Manufacturer:

Finder Relays, Inc.

Datasheet:

-

Package:

-

AINNX NO:

28502869-22.34.0.024.1340

Description:

MODULAR CONTACTOR, 4PST-NO 25A,

Products specifications
  • Mounting Type
    DIN Rail
  • Mfr
    Finder Relays, Inc.
  • Package
    Box
  • Product Status
    Active
  • Contact Materials
    Silver Nickel (AgNi)
  • CoilResistance
    289Ohms
  • RoHS
    Non-Compliant
  • Rated control supply voltage at AC 50 Hz
    24 - 24
  • Type of electrical connection of main circuit
    Screw connection
  • Number of auxiliary contacts as normally open contact
    0
  • Modular version
    Yes
  • Number of normally open contacts as main contact
    4
  • Rated control supply voltage at AC 60 Hz
    24 - 24
  • Voltage type for actuating
    AC/DC
  • Rated operation current Ie at AC-3, 400 V
    10
  • Number of normally closed contacts as main contact
    0
  • Rated operation power at AC-3, 400 V
    4
  • Rated operation current Ie at AC-1, 400 V
    25
  • Rated control supply voltage at DC
    24 - 24
  • Number of auxiliary contacts as normally closed contact
    0
  • Series
    22
  • Operating Temperature

    The operating temperature is the range of ambient temperature within which a power supply, or any other electrical equipment, operate in. This ranges from a minimum operating temperature, to a peak or maximum operating temperature, outside which, the power supply may fail.

    -20°C ~ 50°C
  • Termination Style
    Screw Terminal
  • Contact Form

    A page on a website that allows users to communicate with the site owner. The page has fields for filling in name, address and type of comment. On most company websites, email and mailing addresses are also included; however, the contact form provides an immediate, convenient way for users to ask the company questions.

    4PST-NO (4 Form A)
  • Operate Time

    The time interval between the instant of the occurrence of a specified input condition to a system and the instant of completion of a specified operation.

    18 ms
  • Coil Voltage
    24VAC/DC
  • Switching Voltage

    The maximum switching voltage of a relay is the maximum voltage that can be across the contacts whether the relay is open or closed. Operating a relay with high voltages present can cause arcing, and this in turn erodes the contacts and eventually degrades contact performance.

    250VAC - Nom
  • Coil Current

    A current coil is basically a coil, such as, a wire wrapped around an electrical conductor.

    83 mA
  • Release Time

    In telecommunication, release time is the time interval for a circuit to respond when an enabling signal is discontinued

    40 ms
  • Must Operate Voltage
    19.2 VAC/DC
  • Contact Rating (Current)
    25 A
  • Coil Power
    2.2W
  • Must Release Voltage
    2.4 VAC/DC
  • Features
    Lighted Indicator, Mechanical Indicator, AUTO-ON-OFF Selector
  • Ratings
    IP20
0 Similar Products Remaining