KRPA-14DG-110

TE Connectivity Potter & Brumfield Relays KRPA-14DG-110

Part No:

KRPA-14DG-110

Datasheet:

KRPA Series

Package:

120

ROHS:

AINNX NO:

880150-KRPA-14DG-110

Description:

RELAY GEN PURPOSE 3PDT 10A 110V

Products specifications
  • Factory Lead Time
    18 Weeks
  • Mount
    Socket
  • Mounting Type
    Socketable
  • Package / Case
    120
  • Number of Pins
    11
  • Weight
    84.708375g
  • CoilResistance
    10kOhm
  • Coil Voltage AC
    110V
  • Contact Materials
    Silver Cadmium Oxide (AgCdO)
  • ElectricalLife
    10000000 Cycle(s)
  • Operating Temperature

    The operating temperature is the range of ambient temperature within which a power supply, or any other electrical equipment, operate in. This ranges from a minimum operating temperature, to a peak or maximum operating temperature, outside which, the power supply may fail.

    -45°C~70°C
  • Packaging

    Semiconductor package is a carrier / shell used to contain and cover one or more semiconductor components or integrated circuits. The material of the shell can be metal, plastic, glass or ceramic.

    Tray
  • Series
    KRPA
  • Published
    2007
  • Part Status

    Parts can have many statuses as they progress through the configuration, analysis, review, and approval stages.

    Active
  • Moisture Sensitivity Level (MSL)
    Not Applicable
  • Termination
    Plug
  • ECCN Code
    EAR99
  • Power Rating
    1.2W
  • Depth
    37.3mm
  • Current Rating

    Current rating is the maximum current that a fuse will carry for an indefinite period without too much deterioration of the fuse element.

    10A
  • Reference Standard
    CSA; UL
  • Termination Style
    Plug In, 11 Pin (Octal)
  • Voltage - Rated AC
    240V
  • Approval Agency
    CSA, UL
  • Physical Dimension
    48.8mm x 37.3mm x 34.9mm
  • Insulation Resistance

    The measurement of insulation resistance is carried out by means of a megohmmeter – high resistance range ohmmeter. A general rule-of-thumb is 10 Megohm or more.

    1000000000Ohm
  • Max Voltage Rating (AC)
    240V
  • Throw Configuration
    3PDT
  • Contact Form

    A page on a website that allows users to communicate with the site owner. The page has fields for filling in name, address and type of comment. On most company websites, email and mailing addresses are also included; however, the contact form provides an immediate, convenient way for users to ask the company questions.

    3PDT (3 Form C)
  • Relay Type
    General Purpose
  • Operate Time

    The time interval between the instant of the occurrence of a specified input condition to a system and the instant of completion of a specified operation.

    15 ms
  • Coil Voltage
    110VDC
  • Coil Type

    There are 2 different types of 'coil'; one has copper on it (IUD) and the other contains hormone (Mirena IUS). Both are over 99% effective at protecting against pregnancy.

    Non Latching
  • Switching Voltage

    The maximum switching voltage of a relay is the maximum voltage that can be across the contacts whether the relay is open or closed. Operating a relay with high voltages present can cause arcing, and this in turn erodes the contacts and eventually degrades contact performance.

    240VAC -Max
  • Coil Current

    A current coil is basically a coil, such as, a wire wrapped around an electrical conductor.

    11.5mA
  • Release Time

    In telecommunication, release time is the time interval for a circuit to respond when an enabling signal is discontinued

    10 ms
  • Must Operate Voltage
    82.5VDC
  • Power Consumption

    Power consumption is the amount of input energy (measured in watts) required for an electrical appliance to function. This is opposed to power output which is a measure of the level of performance, of a heat pump for example.

    1.2W
  • Coil Power
    1.5W
  • Contact/Output Supply Type
    AC
  • Relay Action
    MOMENTARY
  • Coil Voltage (DC)
    110V
  • Coil/Input Supply Type
    DC
  • Dielectric Strength Between Open Contacts
    1000 Vrms
  • Input Switching Control Type
    Random
  • Coil Insulation
    Class B
  • Dielectric Strength Between Coil and Contacts
    1000 Vrms
  • Contact Voltage Rating (AC)
    240V
  • Height
    50.8mm
  • Length
    35.7mm
  • Width
    35.687mm
  • REACH SVHC
    Unknown
  • RoHS Status

    RoHS means “Restriction of Certain Hazardous Substances” in the “Hazardous Substances Directive” in electrical and electronic equipment.

    RoHS Compliant
0 Similar Products Remaining