RTE24005F

TE Connectivity Potter & Brumfield Relays RTE24005F

Part No:

RTE24005F

Datasheet:

RT2 Series, F

Package:

DIP

ROHS:

AINNX NO:

868340-RTE24005F

Description:

RELAY GENERAL PURPOSE DPDT 8A 5V

Products specifications
  • Lifecycle Status
    ACTIVE (Last Updated: 5 days ago)
  • Factory Lead Time
    4 Weeks
  • Mount
    Socket
  • Mounting Type
    Through Hole
  • Package / Case
    DIP
  • Number of Pins
    8
  • Weight
    13g
  • CoilResistance
    62Ohm
  • Coil Voltage AC
    5V
  • Contact Materials
    Silver Nickel (AgNi)
  • ElectricalLife
    30000 Cycle(s)
  • Operating Temperature

    The operating temperature is the range of ambient temperature within which a power supply, or any other electrical equipment, operate in. This ranges from a minimum operating temperature, to a peak or maximum operating temperature, outside which, the power supply may fail.

    -40°C~85°C
  • Packaging

    Semiconductor package is a carrier / shell used to contain and cover one or more semiconductor components or integrated circuits. The material of the shell can be metal, plastic, glass or ceramic.

    Tube
  • Series
    RT2
  • Published
    2011
  • Part Status

    Parts can have many statuses as they progress through the configuration, analysis, review, and approval stages.

    Active
  • Moisture Sensitivity Level (MSL)
    1 (Unlimited)
  • Termination
    Plug
  • ECCN Code
    EAR99
  • Voltage - Rated DC
    5V
  • Packing Method
    BOX
  • Depth
    12.7mm
  • Current Rating

    Current rating is the maximum current that a fuse will carry for an indefinite period without too much deterioration of the fuse element.

    8A
  • Reference Standard
    CSA; UL; VDE
  • Termination Style
    PC Pin
  • Voltage - Rated AC
    277V
  • Approval Agency
    CSA, VDE, cULus
  • Physical Dimension
    29mm X 12.7mm X 15.7mm
  • Contact Current(DC)-Max
    8A
  • Sealing
    IMMERSION CLEANABLE CASE
  • ELV
    Compliant
  • Contact Voltage(DC)-Max
    30V
  • Max Voltage Rating (AC)
    400V
  • Throw Configuration
    DPDT
  • Contact Form

    A page on a website that allows users to communicate with the site owner. The page has fields for filling in name, address and type of comment. On most company websites, email and mailing addresses are also included; however, the contact form provides an immediate, convenient way for users to ask the company questions.

    DPDT (2 Form C)
  • Relay Type
    General Purpose
  • Dropout Voltage

    Dropout voltage is the input-to-output differential voltage at which the circuit ceases to regulate against further reductions in input voltage; this point occurs when the input voltage approaches the output voltage.

    500mV
  • Contact Current(AC)-Max
    8A
  • Operate Time

    The time interval between the instant of the occurrence of a specified input condition to a system and the instant of completion of a specified operation.

    8ms
  • Coil Voltage
    5VDC
  • Coil Type

    There are 2 different types of 'coil'; one has copper on it (IUD) and the other contains hormone (Mirena IUS). Both are over 99% effective at protecting against pregnancy.

    Non Latching
  • Switching Voltage

    The maximum switching voltage of a relay is the maximum voltage that can be across the contacts whether the relay is open or closed. Operating a relay with high voltages present can cause arcing, and this in turn erodes the contacts and eventually degrades contact performance.

    400VAC -Max
  • Coil Current

    A current coil is basically a coil, such as, a wire wrapped around an electrical conductor.

    80.6mA
  • Release Time

    In telecommunication, release time is the time interval for a circuit to respond when an enabling signal is discontinued

    6ms
  • Must Operate Voltage
    3.5VDC
  • Power Consumption

    Power consumption is the amount of input energy (measured in watts) required for an electrical appliance to function. This is opposed to power output which is a measure of the level of performance, of a heat pump for example.

    400mW
  • Coil Power
    500mW
  • Must Release Voltage
    0.5VDC
  • Contact/Output Supply Type
    AC/DC
  • Relay Action
    MOMENTARY
  • Coil Voltage (DC)
    5V
  • Coil/Input Supply Type
    DC
  • Seal Rating
    Sealed - Fully
  • Coil Insulation
    Class F
  • Contact Voltage Rating (AC)
    250V
  • Height
    15.7mm
  • Length
    29.0068mm
  • Width
    12.7mm
  • REACH SVHC
    Unknown
  • RoHS Status

    RoHS means “Restriction of Certain Hazardous Substances” in the “Hazardous Substances Directive” in electrical and electronic equipment.

    RoHS Compliant
  • Lead Free
    Lead Free