MK02/0-1A66-500W

Standex-Meder Electronics MK02/0-1A66-500W

Part No:

MK02/0-1A66-500W

Package:

Molded Body

ROHS:

AINNX NO:

7540895-MK02/0-1A66-500W

Description:

STANDEXMEDER MK02/0-1A66-500W REED SENSOR

Products specifications
  • Factory Lead Time
    12 Weeks
  • Mount
    Flanges
  • Package / Case
    Molded Body
  • Actuator Material

    In smart material system, actuator materials have the ability to change the shape, stiffness, position, natural frequency, damping and/or other mechanical characteristics of the smart material systems in response to changes in temperature, electric field and/or magnetic field.

    Magnet
  • Operating Temperature

    The operating temperature is the range of ambient temperature within which a power supply, or any other electrical equipment, operate in. This ranges from a minimum operating temperature, to a peak or maximum operating temperature, outside which, the power supply may fail.

    -30°C~80°C TA
  • Series
    MK02
  • Published
    2003
  • Part Status

    Parts can have many statuses as they progress through the configuration, analysis, review, and approval stages.

    Active
  • Moisture Sensitivity Level (MSL)
    1 (Unlimited)
  • Termination
    Cable
  • Type
    Reed Switch
  • Additional Feature

    Any Feature, including a modified Existing Feature, that is not an Existing Feature.

    IT ALSO OPERATES AT -5 TO 80 DEGREE CENTIGRADE
  • Current Rating

    Current rating is the maximum current that a fuse will carry for an indefinite period without too much deterioration of the fuse element.

    1.25A
  • Termination Style
    Cable Leads
  • Body Breadth
    16.8 mm
  • Output Type
    SPST-NO
  • Lead Length
    500mm
  • Operating Supply Voltage

    The voltage level by which an electrical system is designated and to which certain operating characteristics of the system are related.

    200V
  • Supply Voltage-Max (Vsup)
    180V
  • Contact Resistance
    150mOhm
  • Nominal Supply Current

    Nominal current is the same as the rated current. It is the current drawn by the motor while delivering rated mechanical output at its shaft.

    500mA
  • Throw Configuration
    SPST
  • Max Voltage Rating (DC)
    200V
  • Response Time

    the time taken for a circuit or measuring device, when subjected to a change in input signal, to change its state by a specified fraction of its total response to that change.

    100 µs
  • Switching Voltage

    The maximum switching voltage of a relay is the maximum voltage that can be across the contacts whether the relay is open or closed. Operating a relay with high voltages present can cause arcing, and this in turn erodes the contacts and eventually degrades contact performance.

    200V
  • Sensing Method
    Magnetic
  • Housing
    PBT GLASS FIBRE REINFORCED
  • Measurement Range-Max
    10 mm
  • Measurement Range-Min
    4.5 mm
  • Width
    32.4mm
  • Body Height
    10mm
  • REACH SVHC
    No SVHC
  • RoHS Status

    RoHS means “Restriction of Certain Hazardous Substances” in the “Hazardous Substances Directive” in electrical and electronic equipment.

    ROHS3 Compliant
0 Similar Products Remaining