782XBXM4L-120A

Schneider Electric 782XBXM4L-120A

Part No:

782XBXM4L-120A

Manufacturer:

Schneider Electric

Package:

120

ROHS:

AINNX NO:

21318630-782XBXM4L-120A

Description:

POWER RELAY, DPDT, 120VAC, 15A, PLUG IN; Product Range: MAGNECRAFT - 782 Series;

Products specifications
  • Package / Case
    120
  • Mount
    Plug-In, Socket
  • Mounting Type
    Chassis Mount
  • Number of Pins
    8
  • Weight
    36 g
  • Number of Terminals
    8
  • End Contact Material
    Silver Alloy
  • CoilResistance
    4.43 kΩ
  • Coil Voltage AC
    120 V
  • Contact Materials
    Gold, Silver
  • Voltage Rating (AC)
    300 V
  • Package
    Box
  • Mfr
    Schneider Electric
  • Product Status
    Obsolete
  • Mounting
    Plug In
  • RoHS
    Yes
  • Manufacturer
    Schneider
  • Approvals
    CE, CSA, UL
  • Manufacturer Part Number
    C827002M
  • Enclosure
    Plastic
  • Coil Voltage-Nom
    120 V
  • Operating Temperature-Min
    -40 °C
  • Operating Temperature-Max
    55 °C
  • Rohs Code
    Yes
  • Part Life Cycle Code
    Active
  • Ihs Manufacturer
    SCHNEIDER ELECTRIC SA
  • ElectricalLife
    100000 Cycle(s)
  • Risk Rank
    2.06
  • Operating Temperature

    The operating temperature is the range of ambient temperature within which a power supply, or any other electrical equipment, operate in. This ranges from a minimum operating temperature, to a peak or maximum operating temperature, outside which, the power supply may fail.

    -40°C ~ 55°C
  • Series
    Legacy
  • Termination
    Plug
  • ECCN Code
    EAR99
  • Max Operating Temperature

    The Maximum Operating Temperature is the maximum body temperature at which the thermistor is designed to operate for extended periods of time with acceptable stability of its electrical characteristics.

    55 °C
  • Min Operating Temperature
    -40 °C
  • Depth
    27.9 mm
  • Reach Compliance Code
    unknown
  • Current Rating

    Current rating is the maximum current that a fuse will carry for an indefinite period without too much deterioration of the fuse element.

    15 A
  • Reference Standard
    CE; CSA; UL
  • Termination Style
    Plug In, Quick Connect - 0.187 (4.7mm)
  • Approval Agency
    CE, CSA, UL
  • Body Length or Diameter
    27.9 mm
  • Body Breadth
    21 mm
  • Physical Dimension
    27.9mm x 21mm x 39.1mm
  • Contact Current(DC)-Max
    12 A
  • Contact Voltage(DC)-Max
    28 V
  • Max Voltage Rating (AC)
    120 V
  • Termination Type
    QUICK CONNECT
  • Max Current Rating
    15 A
  • Throw Configuration
    DPDT
  • Contact Current Rating

    The current rating of a contact is defined as the current level that creates a certain temperature rise of the contact spring — usually 20°C or 30°C. Both electrical and thermal factors govern the heat created by the current.

    15 A
  • Contact Form

    A page on a website that allows users to communicate with the site owner. The page has fields for filling in name, address and type of comment. On most company websites, email and mailing addresses are also included; however, the contact form provides an immediate, convenient way for users to ask the company questions.

    DPDT (2 Form C)
  • Relay Type
    General Purpose
  • Contact Current(AC)-Max
    12 A
  • Contact (AC) Max Rating R Load
  • Operate Time

    The time interval between the instant of the occurrence of a specified input condition to a system and the instant of completion of a specified operation.

    20 ms
  • Coil Voltage
    120VAC
  • Coil Type

    There are 2 different types of 'coil'; one has copper on it (IUD) and the other contains hormone (Mirena IUS). Both are over 99% effective at protecting against pregnancy.

    Non-Latching
  • Switching Voltage

    The maximum switching voltage of a relay is the maximum voltage that can be across the contacts whether the relay is open or closed. Operating a relay with high voltages present can cause arcing, and this in turn erodes the contacts and eventually degrades contact performance.

    300 V
  • Coil Current

    A current coil is basically a coil, such as, a wire wrapped around an electrical conductor.

    27.1 mA
  • Release Time

    In telecommunication, release time is the time interval for a circuit to respond when an enabling signal is discontinued

    20 ms
  • Contact (DC) Max Rating R Load
  • Must Operate Voltage
    96 VAC
  • Contact Rating (Current)
    15 A
  • Power Consumption

    Power consumption is the amount of input energy (measured in watts) required for an electrical appliance to function. This is opposed to power output which is a measure of the level of performance, of a heat pump for example.

    900 mW
  • Coil Power
    1.2 W
  • Must Release Voltage
    18 VAC
  • Contact Voltage(AC)-Max
    277 V
  • Contact/Output Supply Type
    AC/DC
  • Coil/Input Supply Type
    AC
  • Seal Rating
    -
  • Coil Insulation
    -
  • Dielectric Strength Between Coil and Contacts
    1600 Vrms
  • Relay Function
    DPDT
  • Relay Form
    2 FORM C
  • Coil Voltage(AC)-Max
    132 V
  • Features
    Lighted Indicator, Test Button
  • Terminal Length
    0.0074 inch
  • Coil Operate Voltage(AC)
    102 V
  • Coil Release Voltage(AC)
    18 V
  • Contacts
    DPDT
  • Height
    35.5 mm
  • Length
    21 mm
  • Body Height
    39.1 mm
  • RoHS Status

    RoHS means “Restriction of Certain Hazardous Substances” in the “Hazardous Substances Directive” in electrical and electronic equipment.

    RoHS Compliant
  • Lead Free
    Lead Free
0 Similar Products Remaining