782XBXC-240A

Schneider 782XBXC-240A

Part No:

782XBXC-240A

Manufacturer:

Schneider

Datasheet:

-

Package:

-

AINNX NO:

29559970-782XBXC-240A

Description:

Products specifications
  • Mounting Type
    Socketable
  • Weight
    36 g
  • Number of Terminals
    8
  • End Contact Material
    Silver Alloy
  • Manufacturer Part Number
    C827143M
  • Manufacturer
    Schneider Electric
  • Package
    Box
  • Mfr
    Schneider Electric
  • Product Status
    Obsolete
  • Contact Materials
    Silver (Ag), Gold (Au)
  • CoilResistance
    17.72 kOhms
  • Coil Voltage-Nom
    240 V
  • Operating Temperature-Min
    -40 °C
  • Operating Temperature-Max
    55 °C
  • Rohs Code
    Yes
  • Part Life Cycle Code
    Active
  • Ihs Manufacturer
    SCHNEIDER ELECTRIC SA
  • ElectricalLife
    100000 Cycle(s)
  • Risk Rank
    2.09
  • Operating Temperature

    The operating temperature is the range of ambient temperature within which a power supply, or any other electrical equipment, operate in. This ranges from a minimum operating temperature, to a peak or maximum operating temperature, outside which, the power supply may fail.

    -40°C ~ 55°C
  • Series
    Legacy
  • ECCN Code
    EAR99
  • Reach Compliance Code
    unknown
  • Reference Standard
    CE; CSA; UL
  • Termination Style
    Plug In, Quick Connect - 0.187 (4.7mm)
  • Body Length or Diameter
    27.9 mm
  • Body Breadth
    21 mm
  • Physical Dimension
    27.9mm x 21mm x 35.5mm
  • Contact Current(DC)-Max
    12 A
  • Contact Voltage(DC)-Max
    28 V
  • Termination Type
    QUICK CONNECT
  • Contact Form

    A page on a website that allows users to communicate with the site owner. The page has fields for filling in name, address and type of comment. On most company websites, email and mailing addresses are also included; however, the contact form provides an immediate, convenient way for users to ask the company questions.

    DPDT (2 Form C)
  • Relay Type
    General Purpose
  • Contact Current(AC)-Max
    12 A
  • Contact (AC) Max Rating R Load
  • Operate Time

    The time interval between the instant of the occurrence of a specified input condition to a system and the instant of completion of a specified operation.

    20 ms
  • Coil Voltage
    240VAC
  • Coil Type

    There are 2 different types of 'coil'; one has copper on it (IUD) and the other contains hormone (Mirena IUS). Both are over 99% effective at protecting against pregnancy.

    Non Latching
  • Switching Voltage

    The maximum switching voltage of a relay is the maximum voltage that can be across the contacts whether the relay is open or closed. Operating a relay with high voltages present can cause arcing, and this in turn erodes the contacts and eventually degrades contact performance.

    300VAC - Max
  • Coil Current

    A current coil is basically a coil, such as, a wire wrapped around an electrical conductor.

    13.5 mA
  • Release Time

    In telecommunication, release time is the time interval for a circuit to respond when an enabling signal is discontinued

    20 ms
  • Contact (DC) Max Rating R Load
  • Must Operate Voltage
    192 VAC
  • Contact Rating (Current)
    15 A
  • Must Release Voltage
    36 VAC
  • Contact Voltage(AC)-Max
    277 V
  • Contact/Output Supply Type
    AC/DC
  • Coil/Input Supply Type
    AC
  • Seal Rating
    -
  • Coil Insulation
    -
  • Dielectric Strength Between Coil and Contacts
    1600 Vrms
  • Relay Function
    DPDT
  • Relay Form
    2 FORM C
  • Coil Voltage(AC)-Max
    264 V
  • Features
    -
  • Terminal Length
    0.0074 inch
  • Coil Operate Voltage(AC)
    204 V
  • Coil Release Voltage(AC)
    36 V
  • Body Height
    35.5 mm
0 Similar Products Remaining