LLE103101

Honeywell Sensing and Productivity Solutions LLE103101

Part No:

LLE103101

Datasheet:

-

Package:

-

AINNX NO:

2980020-LLE103101

Description:

HONEYWELL S&C LLE103101 SENSOR, LEVEL, LIQUID, REAR FIXING

Products specifications
  • Factory Lead Time
    12 Weeks
  • Mount
    Panel, Through Hole
  • Mounting Type
    Panel Mount, M12 Thread
  • Number of Pins
    3
  • Material
    Plastic
  • Housing Material
    Polysulphone
  • Body Material
    Polysulfone, Polysulphone
  • Material - Housing & Prism
    Polysulfone (PES)
  • Voltage Rated

    RATED voltage is the voltage on the nameplate - the "design point" for maximum power throughput and safe thermal operation.

    5V~12V
  • Operating Temperature

    The operating temperature is the range of ambient temperature within which a power supply, or any other electrical equipment, operate in. This ranges from a minimum operating temperature, to a peak or maximum operating temperature, outside which, the power supply may fail.

    -40°C~125°C
  • Series
    LLE
  • Published
    2001
  • Part Status

    Parts can have many statuses as they progress through the configuration, analysis, review, and approval stages.

    Obsolete
  • Moisture Sensitivity Level (MSL)
    1 (Unlimited)
  • Connector Type
    Wire
  • Type
    Liquid
  • Max Operating Temperature

    The Maximum Operating Temperature is the maximum body temperature at which the thermistor is designed to operate for extended periods of time with acceptable stability of its electrical characteristics.

    125°C
  • Min Operating Temperature
    -40°C
  • Current Rating

    Current rating is the maximum current that a fuse will carry for an indefinite period without too much deterioration of the fuse element.

    5mA
  • Output Type
    Push-Pull
  • Max Output Current

    The maximum current that can be supplied to the load.

    10mA
  • Operating Supply Voltage

    The voltage level by which an electrical system is designated and to which certain operating characteristics of the system are related.

    12V
  • Nominal Supply Current

    Nominal current is the same as the rated current. It is the current drawn by the motor while delivering rated mechanical output at its shaft.

    5mA
  • Current
    15mA
  • Output Configuration
    High-Dry
  • Cable Length

    A nautical unit of measure equal to one tenth of a nautical mile or approximately 1 fathoms.

    250mm
  • Output Current

    The rated output current is the maximum load current that a power supply can provide at a specified ambient temperature. A power supply can never provide more current that it's rated output current unless there is a fault, such as short circuit at the load.

    40mA
  • Response Time

    the time taken for a circuit or measuring device, when subjected to a change in input signal, to change its state by a specified fraction of its total response to that change.

    50 μs
  • Rise Time

    In electronics, when describing a voltage or current step function, rise time is the time taken by a signal to change from a specified low value to a specified high value.

    50μs
  • Max Collector Current
    10mA
  • Sensing Distance

    It is the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation. (Normally, it is 70 to 80 % of the maximum operation distance.)

    1 mm
  • Max Supply Voltage (DC)
    12V
  • Min Supply Voltage (DC)
    5V
  • REACH SVHC
    No SVHC
  • RoHS Status

    RoHS means “Restriction of Certain Hazardous Substances” in the “Hazardous Substances Directive” in electrical and electronic equipment.

    Non-RoHS Compliant
  • Lead Free
    Contains Lead
0 Similar Products Remaining