CSDA1BA

Honeywell Sensing and Productivity Solutions CSDA1BA

Part No:

CSDA1BA

Package:

Module, Single Pass Through

ROHS:

AINNX NO:

9797464-CSDA1BA

Description:

HONEYWELL CSDA1BA SENSOR, HALL EFFECT, 0.5A, 5V

Products specifications
  • Factory Lead Time
    10 Weeks
  • Mount
    PCB, Screw
  • Mounting Type
    Through Hole
  • Package / Case
    Module, Single Pass Through
  • Housing Material
    PBT
  • Current Sensing

    Current sensing refers to the generation of the voltage signal which is related to the current passing in the circuit.

    1A
  • Operating Temperature

    The operating temperature is the range of ambient temperature within which a power supply, or any other electrical equipment, operate in. This ranges from a minimum operating temperature, to a peak or maximum operating temperature, outside which, the power supply may fail.

    -25°C~85°C
  • Packaging

    Semiconductor package is a carrier / shell used to contain and cover one or more semiconductor components or integrated circuits. The material of the shell can be metal, plastic, glass or ceramic.

    Bulk
  • Series
    CSDA
  • Published
    1998
  • Part Status

    Parts can have many statuses as they progress through the configuration, analysis, review, and approval stages.

    Active
  • Moisture Sensitivity Level (MSL)
    1 (Unlimited)
  • Termination
    Connector
  • Max Operating Temperature

    The Maximum Operating Temperature is the maximum body temperature at which the thermistor is designed to operate for extended periods of time with acceptable stability of its electrical characteristics.

    85°C
  • Min Operating Temperature
    -25°C
  • Voltage - Supply
    6V~16V
  • Current Rating

    Current rating is the maximum current that a fuse will carry for an indefinite period without too much deterioration of the fuse element.

    12mA
  • Output
    NPN
  • Current - Supply (Max)
    12mA
  • Output Voltage
    400mV
  • Output Type
    Voltage
  • Polarity
    Bidirectional
  • Number of Channels
    1
  • Max Supply Voltage

    In general, the absolute maximum common-mode voltage is VEE-0.3V and VCC+0.3V, but for products without a protection element at the VCC side, voltages up to the absolute maximum rated supply voltage (i.e. VEE+36V) can be supplied, regardless of supply voltage.

    16V
  • Min Supply Voltage

    The minimum supply voltage (V min ) is explored for sequential logic circuits by statistically simulating the impact of within-die process variations and gate-dielectric soft breakdown on data retention and hold time.

    6V
  • Polarization
    Bidirectional
  • Nominal Supply Current

    Nominal current is the same as the rated current. It is the current drawn by the motor while delivering rated mechanical output at its shaft.

    12mA
  • Output Current

    The rated output current is the maximum load current that a power supply can provide at a specified ambient temperature. A power supply can never provide more current that it's rated output current unless there is a fault, such as short circuit at the load.

    20mA
  • Max Supply Current
    12mA
  • Accuracy
    ±0.5%
  • Max Output Voltage

    The maximum output voltage refers to the dynamic area beyond which the output is saturated in the positive or negative direction, and is limited according to the load resistance value.

    400mV
  • Response Time

    the time taken for a circuit or measuring device, when subjected to a change in input signal, to change its state by a specified fraction of its total response to that change.

    100μs
  • Wire/Cable Diameter
    10.92 mm
  • Sensor Type
    Current Switch
  • Sensing Method
    Inductive
  • Max Supply Voltage (DC)
    16V
  • Min Supply Voltage (DC)
    6V
  • For Measuring
    AC/DC
  • REACH SVHC
    Unknown
  • RoHS Status

    RoHS means “Restriction of Certain Hazardous Substances” in the “Hazardous Substances Directive” in electrical and electronic equipment.

    RoHS Compliant
0 Similar Products Remaining