84873221

Crouzet 84873221

Part No:

84873221

Manufacturer:

Crouzet

Package:

120

ROHS:

AINNX NO:

5748375-84873221

Description:

RELAY MONITOR 3PHASE 120-277V

Products specifications
  • Factory Lead Time
    4 Weeks
  • Mount
    DIN Rail
  • Mounting Type
    DIN Rail
  • Package / Case
    120
  • Coil Voltage AC
    277V
  • Operating Temperature

    The operating temperature is the range of ambient temperature within which a power supply, or any other electrical equipment, operate in. This ranges from a minimum operating temperature, to a peak or maximum operating temperature, outside which, the power supply may fail.

    -20°C~50°C
  • Series
    C-Lynx
  • Published
    2006
  • Part Status

    Parts can have many statuses as they progress through the configuration, analysis, review, and approval stages.

    Active
  • Moisture Sensitivity Level (MSL)
    Not Applicable
  • Type
    Voltage Sensing AC
  • Voltage - Supply
    120V~277VAC
  • Number of Outputs
    2
  • Output Type
    Relay
  • Operating Supply Voltage

    The voltage level by which an electrical system is designated and to which certain operating characteristics of the system are related.

    277V
  • Circuit
    SPDT (1 Form C)
  • Throw Configuration
    DPDT
  • Number of Inputs
    3
  • Switching Voltage

    The maximum switching voltage of a relay is the maximum voltage that can be across the contacts whether the relay is open or closed. Operating a relay with high voltages present can cause arcing, and this in turn erodes the contacts and eventually degrades contact performance.

    250V
  • Power Consumption

    Power consumption is the amount of input energy (measured in watts) required for an electrical appliance to function. This is opposed to power output which is a measure of the level of performance, of a heat pump for example.

    3.9W
  • Contact Rating @ Voltage
    5A @ 250VAC
  • Delay Time

    The amount of time by which the arrival of a signal is retarded after transmission through physical equipment or systems.

    0.3 Sec ~ 30 Sec
  • Trip Range

    The maximum distance a piezo stage can move in a single axis.

    120 ~ 277V AC
  • Trip Status
    Energized High
  • Height
    92.6mm
  • Length
    69mm
  • Width
    35mm
  • RoHS Status

    RoHS means “Restriction of Certain Hazardous Substances” in the “Hazardous Substances Directive” in electrical and electronic equipment.

    RoHS Compliant
  • Ratings
    IP30
0 Similar Products Remaining
Documents & Media Download datasheets and manufacturer documentation for Crouzet 84873221.