84873220

Crouzet 84873220

Part No:

84873220

Manufacturer:

Crouzet

Package:

-

ROHS:

AINNX NO:

5748373-84873220

Description:

RELAY MONITOR 3PHASE 220-480V

Products specifications
  • Factory Lead Time
    4 Weeks
  • Mount
    DIN Rail
  • Mounting Type
    DIN Rail
  • Coil Voltage AC
    480V
  • ElectricalLife
    100000 Cycle(s)
  • Operating Temperature

    The operating temperature is the range of ambient temperature within which a power supply, or any other electrical equipment, operate in. This ranges from a minimum operating temperature, to a peak or maximum operating temperature, outside which, the power supply may fail.

    -20°C~50°C
  • Series
    C-Lynx
  • Published
    2006
  • Part Status

    Parts can have many statuses as they progress through the configuration, analysis, review, and approval stages.

    Active
  • Moisture Sensitivity Level (MSL)
    Not Applicable
  • ECCN Code
    EAR99
  • Type
    Phase Loss, Phase Sequence
  • Voltage - Supply
    230V~400VAC
  • Current Rating

    Current rating is the maximum current that a fuse will carry for an indefinite period without too much deterioration of the fuse element.

    5A
  • Reference Standard
    CE; CSA; GL; IEC; UL
  • Voltage - Rated AC
    250V
  • Number of Outputs
    2
  • Output Type
    Relay
  • Operating Supply Voltage

    The voltage level by which an electrical system is designated and to which certain operating characteristics of the system are related.

    480V
  • Circuit
    DPDT (2 Form C)
  • Contact Current(DC)-Max
    5A
  • Throw Configuration
    DPDT
  • Number of Inputs
    3
  • Contact Current(AC)-Max
    5A
  • Operate Time

    The time interval between the instant of the occurrence of a specified input condition to a system and the instant of completion of a specified operation.

    500 ms
  • Switching Voltage

    The maximum switching voltage of a relay is the maximum voltage that can be across the contacts whether the relay is open or closed. Operating a relay with high voltages present can cause arcing, and this in turn erodes the contacts and eventually degrades contact performance.

    250V
  • Release Time

    In telecommunication, release time is the time interval for a circuit to respond when an enabling signal is discontinued

    1500 ms
  • Power Consumption

    Power consumption is the amount of input energy (measured in watts) required for an electrical appliance to function. This is opposed to power output which is a measure of the level of performance, of a heat pump for example.

    2.9W
  • Relay Action
    MOMENTARY
  • Contact Rating @ Voltage
    8A @ 250VAC
  • Delay Time

    The amount of time by which the arrival of a signal is retarded after transmission through physical equipment or systems.

    0.1 Sec ~ 3 Sec
  • Trip Range

    The maximum distance a piezo stage can move in a single axis.

    200 ~ 484V AC
  • Trip Status
    Energized High
  • Height
    92.6mm
  • Length
    65.5mm
  • Width
    35mm
  • RoHS Status

    RoHS means “Restriction of Certain Hazardous Substances” in the “Hazardous Substances Directive” in electrical and electronic equipment.

    RoHS Compliant
  • Lead Free
    Lead Free
0 Similar Products Remaining