AZ9731-1A-12DC4

American Zettler AZ9731-1A-12DC4

Part No:

AZ9731-1A-12DC4

Manufacturer:

American Zettler

Datasheet:

-

Package:

Dust Cover

AINNX NO:

28177086-AZ9731-1A-12DC4

Description:

40A MINI-ISO AUTO RELAY

Products specifications
  • Mounting Type
    Chassis Mount
  • Package / Case
    Dust Cover
  • Weight
    31 g
  • Number of Terminals
    4
  • End Contact Material
    Silver Tin Oxide
  • Mfr
    American Zettler
  • Package
    Tray
  • Product Status
    Active
  • Contact Materials
    Silver Tin Oxide (AgSnO)
  • CoilResistance
    90 Ohms
  • Base Product Number
    AZ9731
  • Relay Construction
    Non-Latching
  • Pick-up Voltage (Max)
    7.8VDC
  • Product Depth (mm)
    46.5(mm)
  • LED Indicator
    No
  • Operating Temp Range
    -40C to 125C
  • Mounting Styles
    Bracket
  • Voltage Rating (VDC)
    75(V)
  • Dropout Volt
    >1.8VDC
  • Seal
    Sealed
  • Rad Hardened
    No
  • Coil Voltage-Nom
    12 V
  • Operating Temperature-Min
    -40 °C
  • Operating Temperature-Max
    125 °C
  • Rohs Code
    Yes
  • Manufacturer Part Number
    AZ9731-1A-12DC4
  • Manufacturer
    American ZETTLER Inc
  • Part Life Cycle Code
    Active
  • Ihs Manufacturer
    AMERICAN ZETTLER INC
  • ElectricalLife
    100000 Cycle(s)
  • Risk Rank
    2.2
  • Manufacturer Series
    AZ9731
  • Series
    -
  • Operating Temperature

    The operating temperature is the range of ambient temperature within which a power supply, or any other electrical equipment, operate in. This ranges from a minimum operating temperature, to a peak or maximum operating temperature, outside which, the power supply may fail.

    -40°C ~ 125°C
  • JESD-609 Code
    e3
  • ECCN Code
    EAR99
  • Type
    Automotive Relay
  • Terminal Finish
    Tin (Sn)
  • Reach Compliance Code
    compliant
  • Pin Count

    a count of all of the component leads (or pins)

    4
  • Termination Style
    Quick Connect - 0.250" (6.3mm)
  • Body Length or Diameter
    26.5 mm
  • Body Breadth
    26.5 mm
  • Physical Dimension
    26.5mm x 26.5mm x 24.5mm
  • Contact Resistance
    100 mΩ
  • Insulation Resistance

    The measurement of insulation resistance is carried out by means of a megohmmeter – high resistance range ohmmeter. A general rule-of-thumb is 10 Megohm or more.

    100000000 Ω
  • Contact Current(DC)-Max
    40 A
  • Contact Voltage(DC)-Max
    75 V
  • Termination Type
    QUICK CONNECT
  • Contact Current Rating

    The current rating of a contact is defined as the current level that creates a certain temperature rise of the contact spring — usually 20°C or 30°C. Both electrical and thermal factors govern the heat created by the current.

    40(A)
  • Contact Form

    A page on a website that allows users to communicate with the site owner. The page has fields for filling in name, address and type of comment. On most company websites, email and mailing addresses are also included; however, the contact form provides an immediate, convenient way for users to ask the company questions.

    SPST-NO (1 Form A)
  • Relay Type
    POWER/SIGNAL RELAY
  • Operate Time

    The time interval between the instant of the occurrence of a specified input condition to a system and the instant of completion of a specified operation.

    7 ms
  • Coil Voltage
    12VDC
  • Coil Type

    There are 2 different types of 'coil'; one has copper on it (IUD) and the other contains hormone (Mirena IUS). Both are over 99% effective at protecting against pregnancy.

    Non Latching
  • Switching Voltage

    The maximum switching voltage of a relay is the maximum voltage that can be across the contacts whether the relay is open or closed. Operating a relay with high voltages present can cause arcing, and this in turn erodes the contacts and eventually degrades contact performance.

    75VDC - Max
  • Coil Current

    A current coil is basically a coil, such as, a wire wrapped around an electrical conductor.

    133.3 mA
  • Release Time

    In telecommunication, release time is the time interval for a circuit to respond when an enabling signal is discontinued

    5 ms
  • Contact (DC) Max Rating R Load
  • Must Operate Voltage
    7.8 VDC
  • Contact Rating (Current)
    40 A
  • Coil Power
    1.6W
  • Must Release Voltage
    1.8 VDC
  • Contact/Output Supply Type
    DC
  • Relay Action
    LATCHED
  • Coil Voltage (DC)
    12
  • Coil/Input Supply Type
    DC
  • Dielectric Strength Between Open Contacts
    500 Vrms
  • Input Switching Control Type
    Random
  • Dielectric Strength Between Coil and Contacts
    500 Vrms
  • Contact (DC) Max Power Rating R Load
  • Relay Function
    SPST
  • Contact Arrangement
    SPST-NO
  • Coil Voltage(DC)-Max
    15.6 V
  • Relay Form
    1 FORM A
  • Coil Operate Voltage(DC)
    7.8 V
  • Features
    Sealed - Fully
  • Terminal Length
    0.011 inch
  • Coil Suppression Diode

    A coil spike suppression diode is a protection device across the contactor coil. Energizing the contactor coil creates a magnetic field that forces the solenoid arm to engage the contacts. When the contactor is turned off, the magnetic field collapses causing a back “voltage spike” that can damage the controller.

    No
  • Product Length (mm)
    35.5(mm)
  • Body Height
    24.5 mm
  • Product Height (mm)
    67.3(mm)
0 Similar Products Remaining