AZ9891J-2C-12DE

American Zettler AZ9891J-2C-12DE

Part No:

AZ9891J-2C-12DE

Manufacturer:

American Zettler

Datasheet:

-

Package:

-

AINNX NO:

28172861-AZ9891J-2C-12DE

Description:

30A SUB-MICRO AUTO RELAY

Products specifications
  • Mounting Type
    Through Hole
  • Mfr
    American Zettler
  • Package
    Tray
  • Product Status
    Active
  • Contact Materials
    Silver Tin Oxide (AgSnO)
  • CoilResistance
    180 Ohms
  • Base Product Number
    AZ9891J
  • Rohs Code
    Yes
  • Manufacturer Part Number
    AZ9891J-2C-12DE
  • Manufacturer
    American ZETTLER Inc
  • Part Life Cycle Code
    Active
  • Ihs Manufacturer
    AMERICAN ZETTLER INC
  • Risk Rank
    5.64
  • Series
    -
  • Operating Temperature

    The operating temperature is the range of ambient temperature within which a power supply, or any other electrical equipment, operate in. This ranges from a minimum operating temperature, to a peak or maximum operating temperature, outside which, the power supply may fail.

    -40°C ~ 85°C
  • Reach Compliance Code
    compliant
  • Termination Style
    PC Pin
  • Contact Form

    A page on a website that allows users to communicate with the site owner. The page has fields for filling in name, address and type of comment. On most company websites, email and mailing addresses are also included; however, the contact form provides an immediate, convenient way for users to ask the company questions.

    DPDT (2 Form C)
  • Operate Time

    The time interval between the instant of the occurrence of a specified input condition to a system and the instant of completion of a specified operation.

    10 ms
  • Coil Voltage
    12VDC
  • Coil Type

    There are 2 different types of 'coil'; one has copper on it (IUD) and the other contains hormone (Mirena IUS). Both are over 99% effective at protecting against pregnancy.

    Non Latching
  • Switching Voltage

    The maximum switching voltage of a relay is the maximum voltage that can be across the contacts whether the relay is open or closed. Operating a relay with high voltages present can cause arcing, and this in turn erodes the contacts and eventually degrades contact performance.

    16VDC - Max
  • Coil Current

    A current coil is basically a coil, such as, a wire wrapped around an electrical conductor.

    66.7 mA
  • Release Time

    In telecommunication, release time is the time interval for a circuit to respond when an enabling signal is discontinued

    10 ms
  • Must Operate Voltage
    7.2 VDC
  • Contact Rating (Current)
    30 A
  • Coil Power
    800mW
  • Must Release Voltage
    1 VDC
  • Features
    Sealed - Fully
0 Similar Products Remaining