AHI02510

ZETTLER AHI02510

Part No:

AHI02510

Manufacturer:

ZETTLER

Datasheet:

-

Package:

2812 (7132 Metric)

AINNX NO:

34323423-AHI02510

Description:

Transformer, Energy Limiting, Bobbin, 1, Freq 50/60Hz, Pri 115/230VAC, PCB

Products specifications
  • Mounting Type
    Surface Mount
  • Package / Case
    2812 (7132 Metric)
  • Mount
    PCB
  • Weight
    113.398093 g
  • Lead Free Status / RoHS Status
    --
  • Voltage Rated

    RATED voltage is the voltage on the nameplate - the "design point" for maximum power throughput and safe thermal operation.

    16V
  • Lifetime @ Temp.
    --
  • Approvals
    UL, VDE
  • RoHS
    Compliant
  • Package
    Box
  • Mfr
    Zettler Magnetics
  • Product Status
    Active
  • Operating Temperature

    The operating temperature is the range of ambient temperature within which a power supply, or any other electrical equipment, operate in. This ranges from a minimum operating temperature, to a peak or maximum operating temperature, outside which, the power supply may fail.

    -55°C ~ 125°C
  • Series
    TANTAMOUNT®, 595D
  • Packaging

    Semiconductor package is a carrier / shell used to contain and cover one or more semiconductor components or integrated circuits. The material of the shell can be metal, plastic, glass or ceramic.

    Tape & Reel (TR)
  • Size / Dimension
    0.280 L x 0.126 W (7.10mm x 3.20mm)
  • Tolerance
    ±20%
  • Part Status

    Parts can have many statuses as they progress through the configuration, analysis, review, and approval stages.

    Active
  • Moisture Sensitivity Level (MSL)
    --
  • Type
    Conformal Coated
  • Capacitance
    100µF
  • Power Rating
    2.5 W
  • Termination Style
    PC Pin
  • Voltage - Isolation
    4200V
  • ESR (Equivalent Series Resistance)
    270 mOhm
  • Failure Rate

    the frequency with which an engineered system or component fails, expressed in failures per unit of time. It is usually denoted by the Greek letter λ (lambda) and is often used in reliability engineering.

    --
  • Lead Spacing

    the distance between two baselines of lines of type. The word 'leading' originates from the strips of lead hand-typesetters used to use to space out lines of text evenly. The word leading has stuck, but essentially it's a typographer's term for line spacing.

    --
  • Current - Output (Max)
    Parallel 500mA, Series 250mA
  • Manufacturer Size Code
    C
  • Power - Max
    2.5VA
  • Voltage - Primary
    115V, 230V
  • Primary Winding(s)
    Dual, Multiple Taps
  • Center Tap

    In electronics, a center tap (CT) is a contact made to a point halfway along a winding of a transformer or inductor, or along the element of a resistor or a potentiometer.

    No
  • Voltage - Secondary (Full Load)
    Parallel 5V, Series 10V
  • Secondary Winding(s)
    Dual, Multiple Taps
  • Features
    General Purpose
  • Height Seated (Max)
    0.110 (2.80mm)
  • Width
    36.4 mm
  • Height
    28.8 mm
  • Length
    41.3 mm
0 Similar Products Remaining