RD1C-48S

World Products RD1C-48S

Part No:

RD1C-48S

Manufacturer:

World Products

Datasheet:

-

Package:

-

AINNX NO:

41890291-RD1C-48S

Description:

Electromechanical Relay 48VDC 6.4KOhm 12A SPDT(19.6x15.4x15)mm THT Industrial Relay

Products specifications
  • Mount
    Through Hole
  • Mounting Feature

    a process by which the operating system makes files and directories on a storage device (such as hard drive, CD-ROM, or network share) available for users to access via the computer's file system.

    THROUGH HOLE-STRAIGHT MOUNT
  • Number of Pins
    5
  • Weight
    9
  • Number of Terminals
    5
  • End Contact Material
    Silver Alloy
  • RoHS
    Yes
  • Relay Construction
    Non-Latching
  • Pick-up Voltage (Max)
    36VDC
  • Product Depth (mm)
    15.4(mm)
  • LED Indicator
    Yes
  • Operating Temp Range
    -40C to 85C
  • Mounting Styles
    Through Hole
  • Contact Materials
    Silver
  • Voltage Rating (VDC)
    125(V)
  • Dropout Volt
    2.4VDC
  • Seal
    Sealed
  • Rad Hardened
    No
  • CoilResistance
    6400(ohm)
  • Coil Voltage-Nom
    48
  • Operating Temperature-Min
    -40
  • Operating Temperature-Max
    85
  • ElectricalLife
    100000
  • Manufacturer Series
    RD
  • Type
    Industrial Relay
  • Max Operating Temperature

    The Maximum Operating Temperature is the maximum body temperature at which the thermistor is designed to operate for extended periods of time with acceptable stability of its electrical characteristics.

    85 °C
  • Min Operating Temperature
    -40 °C
  • Pin Count

    a count of all of the component leads (or pins)

    5
  • Reference Standard
    UL
  • Termination Style
    PC Pin
  • Body Length or Diameter
    19.6
  • Body Breadth
    15.4
  • Physical Dimension
    19.6mm x 15.4mm x 15mm
  • Contact Resistance
    50
  • Insulation Resistance

    The measurement of insulation resistance is carried out by means of a megohmmeter – high resistance range ohmmeter. A general rule-of-thumb is 10 Megohm or more.

    10000000
  • Contact Current(DC)-Max
    12
  • Contact Voltage(DC)-Max
    125
  • Max Voltage Rating (AC)
    250 V
  • Termination Type
    SOLDER
  • Max Current Rating
    12 A
  • Throw Configuration
    SPDT
  • Max Voltage Rating (DC)
    125 V
  • Contact Current Rating

    The current rating of a contact is defined as the current level that creates a certain temperature rise of the contact spring — usually 20°C or 30°C. Both electrical and thermal factors govern the heat created by the current.

    12(A)
  • Contact Form

    A page on a website that allows users to communicate with the site owner. The page has fields for filling in name, address and type of comment. On most company websites, email and mailing addresses are also included; however, the contact form provides an immediate, convenient way for users to ask the company questions.

    1 Form C
  • Relay Type
    POWER/SIGNAL RELAY
  • Contact Current(AC)-Max
    12
  • Operate Time

    The time interval between the instant of the occurrence of a specified input condition to a system and the instant of completion of a specified operation.

    8(ms)
  • Coil Current

    A current coil is basically a coil, such as, a wire wrapped around an electrical conductor.

    7.5(mA)
  • Release Time

    In telecommunication, release time is the time interval for a circuit to respond when an enabling signal is discontinued

    5
  • Coil Power
    360
  • Contact Voltage(AC)-Max
    250
  • Contact/Output Supply Type
    AC/DC
  • Relay Action
    MOMENTARY
  • Coil Voltage (DC)
    48
  • Coil/Input Supply Type
    DC
  • PCB Hole Count
    5
  • Input Switching Control Type
    Random
  • Relay Function
    SPDT
  • Contact Arrangement
    SPDT
  • Coil Voltage(DC)-Max
    48
  • Coil Current(DC)-Max
    .008
  • Relay Form
    1 FORM C
  • Coil Operate Voltage(DC)
    36
  • Coil Release Voltage(DC)
    2.4
  • Terminal Length
    .003
  • Coil Suppression Diode

    A coil spike suppression diode is a protection device across the contactor coil. Energizing the contactor coil creates a magnetic field that forces the solenoid arm to engage the contacts. When the contactor is turned off, the magnetic field collapses causing a back “voltage spike” that can damage the controller.

    Yes
  • Voltage Rating (VAC)
    250(V)
  • Product Length (mm)
    19.6(mm)
  • Body Height
    15
  • Product Height (mm)
    15(mm)
0 Similar Products Remaining