PTCCL05H150HBC001

Vishay PTCCL05H150HBC001

Part No:

PTCCL05H150HBC001

Manufacturer:

Vishay

Datasheet:

-

Package:

Axial

AINNX NO:

35583125-PTCCL05H150HBC001

Description:

PTC RESET FUSE

Products specifications
  • Package / Case
    Axial
  • Mounting Type
    Through Hole
  • Supplier Device Package
    Axial
  • Package
    Tape & Reel (TR)
  • Base Product Number
    PTCCL
  • Mfr
    Vishay Beyschlag/Draloric/BC Components
  • Product Status
    Obsolete
  • Resistance - 25°C (Typ)
    1.9 kOhms
  • Operating Temperature

    The operating temperature is the range of ambient temperature within which a power supply, or any other electrical equipment, operate in. This ranges from a minimum operating temperature, to a peak or maximum operating temperature, outside which, the power supply may fail.

    -65°C ~ 175°C
  • Series
    Military, MIL-R-10509/7, RN55
  • Packaging

    Semiconductor package is a carrier / shell used to contain and cover one or more semiconductor components or integrated circuits. The material of the shell can be metal, plastic, glass or ceramic.

    Bulk
  • Size / Dimension
    0.090 Dia x 0.240 L (2.29mm x 6.10mm)
  • Tolerance
    ±0.1%
  • Part Status

    Parts can have many statuses as they progress through the configuration, analysis, review, and approval stages.

    Active
  • Number of Terminations
    2
  • Temperature Coefficient

    The resistance-change factor per degree Celsius of temperature change is called the temperature coefficient of resistance. This factor is represented by the Greek lower-case letter “alpha” (α). A positive coefficient for a material means that its resistance increases with an increase in temperature.

    ±50ppm/°C
  • Type
    Ceramic
  • Resistance
    324 Ohms
  • Composition
    Metal Film
  • Power (Watts)
    0.125W, 1/8W
  • Approval Agency
    UR
  • Failure Rate

    the frequency with which an engineered system or component fails, expressed in failures per unit of time. It is usually denoted by the Greek letter λ (lambda) and is often used in reliability engineering.

    --
  • Lead Spacing

    the distance between two baselines of lines of type. The word 'leading' originates from the strips of lead hand-typesetters used to use to space out lines of text evenly. The word leading has stuck, but essentially it's a typographer's term for line spacing.

    0.197 (5.00mm)
  • Current - Max
    110 mA
  • Current - Hold (Ih) (Max)
    15 mA
  • Voltage - Max
    265V
  • Current - Trip (It)
    23 mA
  • Features
    Flame Retardant Coating, Military, Moisture Resistant, Safety
  • Height Seated (Max)
    --
  • Thickness (Max)
    -
  • Ratings
    -
0 Similar Products Remaining