OZ-SS-112LF,000

TE Connectivity OZ-SS-112LF,000

Part No:

OZ-SS-112LF,000

Manufacturer:

TE Connectivity

Datasheet:

-

Package:

-

AINNX NO:

35550743-OZ-SS-112LF,000

Description:

OZ Series Power PCB Relay Flux Proof 1-Pole 12 VDC 270 Ohm 540 mW 1-Form C (CO) Silver Cadmium Oxide

Products specifications
  • Mounting Type
    Through Hole
  • Termination Method
    PC Pins
  • Minimum Dropout Voltage
    0.6 Vdc
  • Mounting
    Through Hole
  • Package
    Tube
  • Base Product Number
    OZ-SS
  • Mfr
    TE Connectivity Potter & Brumfield Relays
  • Product Status
    Obsolete
  • Contact Materials
    Silver Cadmium Oxide (AgCdO)
  • CoilResistance
    270 Ohms
  • Operating Temperature

    The operating temperature is the range of ambient temperature within which a power supply, or any other electrical equipment, operate in. This ranges from a minimum operating temperature, to a peak or maximum operating temperature, outside which, the power supply may fail.

    -30 to 70 °C
  • Series
    OZ, OEG
  • Pin Count

    a count of all of the component leads (or pins)

    8
  • Termination Style
    PC Pin
  • Contact Form

    A page on a website that allows users to communicate with the site owner. The page has fields for filling in name, address and type of comment. On most company websites, email and mailing addresses are also included; however, the contact form provides an immediate, convenient way for users to ask the company questions.

    SPDT (1 Form C)
  • Relay Type
    General Purpose
  • Operate Time

    The time interval between the instant of the occurrence of a specified input condition to a system and the instant of completion of a specified operation.

    20 ms
  • Coil Voltage
    12VDC
  • Coil Type

    There are 2 different types of 'coil'; one has copper on it (IUD) and the other contains hormone (Mirena IUS). Both are over 99% effective at protecting against pregnancy.

    Non Latching
  • Switching Voltage

    The maximum switching voltage of a relay is the maximum voltage that can be across the contacts whether the relay is open or closed. Operating a relay with high voltages present can cause arcing, and this in turn erodes the contacts and eventually degrades contact performance.

    240VAC
  • Release Time

    In telecommunication, release time is the time interval for a circuit to respond when an enabling signal is discontinued

    8 ms
  • Must Operate Voltage
    9 VDC
  • Contact Rating (Current)
    16 A
  • Must Release Voltage
    0.6 VDC
  • Seal Rating
    Sealed - Flux Protection
  • Coil Insulation
    Class F
  • Product
    Power Relays
  • Product Length
    29.2 mm
0 Similar Products Remaining