OJT-SS-105LM,000

TE Connectivity OJT-SS-105LM,000

Part No:

OJT-SS-105LM,000

Manufacturer:

TE Connectivity

Datasheet:

-

Package:

-

AINNX NO:

37031854-OJT-SS-105LM,000

Description:

Power Relay 5VDC 5A SPST-NO(18.2mm 10.2mm 14.7mm) THT

Products specifications
  • Mounting Type
    PCB Mount
  • Standards Met
    CQC08001025528, TUV R 50139166, UL E82292, UL TV-5, VDE 40007630
  • CoilResistance
    100Ω
  • Package
    Bulk
  • Base Product Number
    OJT-SS
  • Mfr
    TE Connectivity Potter & Brumfield Relays
  • Product Status
    Active
  • Contact Materials
    Silver Tin Oxide (AgSnO)
  • Series
    OJ
  • Operating Temperature

    The operating temperature is the range of ambient temperature within which a power supply, or any other electrical equipment, operate in. This ranges from a minimum operating temperature, to a peak or maximum operating temperature, outside which, the power supply may fail.

    -30°C ~ 85°C
  • Applications
    Appliances, Consumer Electronics, Industrial Control
  • Depth
    10.2mm
  • Termination Style
    PC Pin
  • Number of Poles
    1
  • Contact Form

    A page on a website that allows users to communicate with the site owner. The page has fields for filling in name, address and type of comment. On most company websites, email and mailing addresses are also included; however, the contact form provides an immediate, convenient way for users to ask the company questions.

    SPST-NO (1 Form A)
  • Relay Type
    General Purpose
  • Operate Time

    The time interval between the instant of the occurrence of a specified input condition to a system and the instant of completion of a specified operation.

    15 ms
  • Coil Voltage
    5V dc
  • Coil Type

    There are 2 different types of 'coil'; one has copper on it (IUD) and the other contains hormone (Mirena IUS). Both are over 99% effective at protecting against pregnancy.

    Non Latching
  • Switching Voltage

    The maximum switching voltage of a relay is the maximum voltage that can be across the contacts whether the relay is open or closed. Operating a relay with high voltages present can cause arcing, and this in turn erodes the contacts and eventually degrades contact performance.

    250VAC - Max
  • Coil Current

    A current coil is basically a coil, such as, a wire wrapped around an electrical conductor.

    50 mA
  • Release Time

    In telecommunication, release time is the time interval for a circuit to respond when an enabling signal is discontinued

    4 ms
  • Must Operate Voltage
    3.75 VDC
  • Contact Rating (Current)
    5 A
  • Coil Power
    200mW
  • Must Release Voltage
    0.25 VDC
  • Seal Rating
    Sealed - Flux Protection
  • Coil Insulation
    -
  • Switching Current
    5A
  • Contact Configuration
    SPST
  • Product
    Power Relays
  • Features
    -
  • Height
    14.7mm
  • Length
    18.2mm
0 Similar Products Remaining