Description:

Signal Relay 12VDC 2A DPDT(10x6x5.65)mm THT Medical

Products specifications
  • Lifecycle Status
    Production (Last Updated: 4 days ago)
  • Mounting Type
    Through Hole
  • Contact Plating

    Contact plating (finish) provides corrosion protection for base metals and optimizes the mechanical and electrical properties of the contact interfaces.

    Gold
  • Mount
    PCB, Through Hole
  • Surface Mount

    having leads that are designed to be soldered on the side of a circuit board that the body of the component is mounted on.

    NO
  • Mounting Feature

    a process by which the operating system makes files and directories on a storage device (such as hard drive, CD-ROM, or network share) available for users to access via the computer's file system.

    THROUGH HOLE-STRAIGHT MOUNT
  • Number of Pins
    8
  • Weight
    21.262142 g
  • Lead Free Status / RoHS Status
    --
  • Contact Materials
    Palladium (Pd), Ruthenium (Ru), Gold (Au)
  • Turn Off Voltage (Min)
    1.2 VDC
  • Turn On Voltage (Max)
    9 VDC
  • CoilResistance
    1.03 kOhms
  • Package
    Tube
  • Base Product Number
    IM
  • Mfr
    TE Connectivity Potter & Brumfield Relays
  • Product Status
    Active
  • Schedule B
    8536410030/8536410030/8536410030/8536410030/8536410030, 8536490050
  • Coil Voltage AC
    12 V
  • Manufacturer Lifecycle Status
    ACTIVE (Last Updated: 4 days ago)
  • RoHS
    Compliant
  • Dimensions
    10 x 6 x 5.65mm
  • Maximum Operating Temperature

    the maximum body temperature at which the thermistor is designed to operate for extended periods of time with acceptable stability of its electrical characteristics.

    +85°C
  • Minimum Operating Temperature
    -40°C
  • Unit Weight
    0.035274 oz
  • Factory Pack QuantityFactory Pack Quantity
    1000
  • Part # Aliases
    2-1462037-7
  • Manufacturer
    TE Connectivity
  • Brand
    TE Connectivity / P&B
  • Package Description
    ROHS COMPLIANT
  • Operating Temperature-Min
    -55 °C
  • Isolation-Max
    -18.8 dB
  • Operating Temperature-Max
    85 °C
  • Rohs Code
    Yes
  • Operating Frequency (Max)
    900 MHz
  • Manufacturer Part Number
    IM06TS
  • Insertion Loss-Max
    -0.33 dB
  • Part Life Cycle Code
    Active
  • Samacsys Description
    DPDT telecom PCB relay, 2A 12Vdc coil TE Connectivity DPDT PCB Mount Non-Latching Relay, 12V dc Coil, 2 A
  • Ihs Manufacturer
    TE CONNECTIVITY LTD
  • ElectricalLife
    100000 Cycle(s)
  • Risk Rank
    0.68
  • Packaging

    Semiconductor package is a carrier / shell used to contain and cover one or more semiconductor components or integrated circuits. The material of the shell can be metal, plastic, glass or ceramic.

    Tube
  • Operating Temperature

    The operating temperature is the range of ambient temperature within which a power supply, or any other electrical equipment, operate in. This ranges from a minimum operating temperature, to a peak or maximum operating temperature, outside which, the power supply may fail.

    -40°C ~ 85°C
  • Series
    IM, AXICOM
  • Part Status

    Parts can have many statuses as they progress through the configuration, analysis, review, and approval stages.

    Active
  • Moisture Sensitivity Level (MSL)
    --
  • Termination
    PCB
  • ECCN Code
    EAR99
  • Type
    Low Profile
  • Max Operating Temperature

    The Maximum Operating Temperature is the maximum body temperature at which the thermistor is designed to operate for extended periods of time with acceptable stability of its electrical characteristics.

    85 °C
  • Min Operating Temperature
    -40 °C
  • Applications
    Signal
  • Additional Feature

    Any Feature, including a modified Existing Feature, that is not an Existing Feature.

    LOW PROFILE
  • HTS Code

    HTS (Harmonized Tariff Schedule) codes are product classification codes between 8-1 digits. The first six digits are an HS code, and the countries of import assign the subsequent digits to provide additional classification. U.S. HTS codes are 1 digits and are administered by the U.S. International Trade Commission.

    8536.49.00.50
  • Subcategory
    Relays
  • Packing Method
    TUBE
  • Depth
    6 mm
  • Reach Compliance Code
    compliant
  • Current Rating

    Current rating is the maximum current that a fuse will carry for an indefinite period without too much deterioration of the fuse element.

    2 A
  • Reference Standard
    CECC; CSA; IEC; UL
  • Termination Style
    PC Pin
  • Body Length or Diameter
    10 mm
  • Number of Contacts
    2
  • Body Breadth
    6 mm
  • Physical Dimension
    10mm x 6mm x 5.65mm
  • Brand Name
    Axicom
  • Contact Resistance
    50 mΩ
  • Contact Current(DC)-Max
    2 A
  • Sealing
    IP67
  • Contact Voltage(DC)-Max
    220 V
  • Max Voltage Rating (AC)
    250 V
  • Termination Type
    SOLDER
  • Max Current Rating
    2 A
  • Number of Poles
    2
  • Throw Configuration
    DPDT
  • Max Voltage Rating (DC)
    220 V
  • Contact Current Rating

    The current rating of a contact is defined as the current level that creates a certain temperature rise of the contact spring — usually 20°C or 30°C. Both electrical and thermal factors govern the heat created by the current.

    2 A
  • Contact Termination
    Solder Pin
  • Contact Form

    A page on a website that allows users to communicate with the site owner. The page has fields for filling in name, address and type of comment. On most company websites, email and mailing addresses are also included; however, the contact form provides an immediate, convenient way for users to ask the company questions.

    DPDT (2 Form C)
  • Relay Type
    Telecom
  • Terminal Type

    Terminal type or emulation specifies how your computer and the host computer to which you are connected exchange information.

    Through Hole
  • Product Type

    a group of products which fulfill a similar need for a market segment or market as a whole.

    PCB Relays
  • Operating Temperature Range

    An operating temperature is the allowable temperature range of the local ambient environment at which an electrical or mechanical device operates. The device will operate effectively within a specified temperature range which varies based on the device function and application context, and ranges from the minimum operating temperature to the maximum operating temperature (or peak operating temperature).

    -40 → +85°C
  • Contact Current(AC)-Max
    2 A
  • Contact (AC) Max Rating R Load
  • Operate Time

    The time interval between the instant of the occurrence of a specified input condition to a system and the instant of completion of a specified operation.

    3ms
  • Coil Voltage
    12VDC
  • Coil Type

    There are 2 different types of 'coil'; one has copper on it (IUD) and the other contains hormone (Mirena IUS). Both are over 99% effective at protecting against pregnancy.

    Non Latching
  • Switching Voltage

    The maximum switching voltage of a relay is the maximum voltage that can be across the contacts whether the relay is open or closed. Operating a relay with high voltages present can cause arcing, and this in turn erodes the contacts and eventually degrades contact performance.

    250VAC, 220VDC - Max
  • Coil Current

    A current coil is basically a coil, such as, a wire wrapped around an electrical conductor.

    11.6mA
  • Release Time

    In telecommunication, release time is the time interval for a circuit to respond when an enabling signal is discontinued

    3ms
  • Contact (DC) Max Rating R Load
  • Must Operate Voltage
    9 VDC
  • Contact Rating (Current)
    2A
  • Power Consumption

    Power consumption is the amount of input energy (measured in watts) required for an electrical appliance to function. This is opposed to power output which is a measure of the level of performance, of a heat pump for example.

    140 mW
  • Coil Power
    140 mW
  • Must Release Voltage
    1.2 VDC
  • Contact Voltage(AC)-Max
    250 V
  • Contact/Output Supply Type
    AC/DC
  • Relay Action
    MOMENTARY
  • Coil Voltage (DC)
    12 V
  • Coil/Input Supply Type
    DC
  • Operating Frequency-Min
    100 MHz
  • VSWR
    1.49
  • Insertion Loss (dB)
    -0.03 dB
  • Seal Rating
    Sealed - Hermetically
  • Coil Insulation
    -
  • Ambient Temperature Range High

    This varies from person to person, but it is somewhere between 68 and 77 degrees F on average. The temperature setting that is comfortable for an individual may fluctuate with humidity and outside temperature as well. The temperature of an air conditioned room can also be considered ambient temperature.

    85 °C
  • Switching Current
    2 A
  • Relay Function
    DPDT
  • Coil Voltage(DC)-Max
    12 V
  • Contact Configuration
    DPDT
  • Coil Current(DC)-Max
    0.012 A
  • Coil Operate Voltage(DC)
    8.4 V
  • Coil Release Voltage(DC)
    1.2 V
  • Product
    Low Signal Relays
  • Contact Voltage Rating (DC)
    220 V
  • Switching Time
    18 ms
  • Features
    Sealed - Hermetically
  • Product Category

    a particular group of related products.

    Low Signal Relays - PCB
  • Width
    6 mm
  • Height
    5.65 mm
  • Length
    254 mm
  • Body Height
    5.65 mm
  • REACH SVHC
    Unknown
  • Ratings
    IP67
0 Similar Products Remaining