5903-1010-030

TE Connectivity 5903-1010-030

Part No:

5903-1010-030

Manufacturer:

TE Connectivity

Datasheet:

-

Package:

-

AINNX NO:

32291558-5903-1010-030

Description:

Linear Type Potentiometer Position Sensor 10K Ohm

Products specifications
  • Surface Mount

    having leads that are designed to be soldered on the side of a circuit board that the body of the component is mounted on.

    NO
  • Mounting Type
    Custom
  • Terminal Shape
    FLEXIBLE WIRE
  • Mounting Feature

    a process by which the operating system makes files and directories on a storage device (such as hard drive, CD-ROM, or network share) available for users to access via the computer's file system.

    CHASSIS MOUNT
  • Number of Terminals
    3
  • Manufacturer Part Number
    5903-1010-030
  • Part Life Cycle Code
    Transferred
  • Ihs Manufacturer
    MEASUREMENT SPECIALTIES INC
  • Package Description
    Chassis Mount,
  • Risk Rank
    5.69
  • Operating Temperature-Max
    125 °C
  • Operating Temperature-Min
    -65 °C
  • Package Diameter
    7.92 mm
  • Package Length
    44.7 mm
  • Package Style
    Chassis Mount
  • Rotational Angle
    360 deg
  • Package
    Bag
  • Base Product Number
    5903
  • Mfr
    TE Connectivity Measurement Specialties
  • Product Status
    Active
  • Measures
    Linear Position
  • Maximum Operating Temperature

    the maximum body temperature at which the thermistor is designed to operate for extended periods of time with acceptable stability of its electrical characteristics.

    + 125 C
  • Minimum Operating Temperature
    - 65 C
  • Resistance Range
    10 kOhms
  • Operating Temperature

    The operating temperature is the range of ambient temperature within which a power supply, or any other electrical equipment, operate in. This ranges from a minimum operating temperature, to a peak or maximum operating temperature, outside which, the power supply may fail.

    -65°C ~ 125°C
  • Series
    5903
  • Tolerance
    10%
  • ECCN Code
    EAR99
  • Temperature Coefficient

    The resistance-change factor per degree Celsius of temperature change is called the temperature coefficient of resistance. This factor is represented by the Greek lower-case letter “alpha” (α). A positive coefficient for a material means that its resistance increases with an increase in temperature.

    500 ppm/°C
  • Resistance
    10000 Ω
  • Voltage - Supply
    -
  • Construction
    Precision
  • Resistor Type
    POTENTIOMETER
  • Reach Compliance Code
    unknown
  • Output
    Resistive
  • Termination Style
    Wire Leads
  • Rated Power Dissipation (P)
    1 W
  • Actuator Type
    SHAFT
  • Output Type
    Analog - Voltage
  • Lead Length
    152.4 mm
  • Lead Diameter
    0.254 mm
  • Rated Temperature
    70 °C
  • Number of Turns
    1
  • Actuator Orientation

    A valve actuator is the mechanism for opening and closing a valve. Manually operated valves require someone in attendance to adjust them using a direct or geared mechanism attached to the valve stem. Power-operated actuators, using gas pressure, hydraulic pressure or electricity, allow a valve to be adjusted remotely, or allow rapid operation of large valves. Power-operated valve actuators may be the final elements of an automatic control loop which automatically regulates some flow, level or other process. Actuators may be only to open and close the valve, or may allow intermediate positioning; some valve actuators include switches or other ways to remotely indicate the position of the valve.

    VERTICAL
  • Linearity
    ±1%
  • Resistance Tolerance

    Tolerance is the percentage of error in the resistor's resistance, or how much more or less you can expect a resistor's actual measured resistance to be from its stated resistance. A gold tolerance band is 5% tolerance, silver is 10%, and no band at all would mean a 20% tolerance.

    ±10%
  • Ganging Number
    1
  • For Measuring
    Linear Position
  • Output Signal

    signal that comes out of an electronic system. output. signal, signaling, sign - any nonverbal action or gesture that encodes a message; "signals from the boat suddenly stopped" printout - the output of a computer in printed form.

    -
  • Rotation Angle - Electrical, Mechanical
    -
  • Resistance Law
    LINEAR
  • Product
    Linear Position Sensors
  • Linear Range

    The range of concentrations where the signals are directly proportional to the concentration of the analyte in the sample.

    0 ~ 25.40mm (0 ~ 1.00)
0 Similar Products Remaining