1825086-2

TE Connectivity 1825086-2

Part No:

1825086-2

Manufacturer:

TE Connectivity

Datasheet:

-

Package:

-

AINNX NO:

28103055-1825086-2

Description:

SMD Tactile Switches ROHS

Products specifications
  • Factory Lead Time
    9 Weeks
  • Contact Plating

    Contact plating (finish) provides corrosion protection for base metals and optimizes the mechanical and electrical properties of the contact interfaces.

    Silver
  • Mounting Type
    Surface Mount
  • Actuator Material

    In smart material system, actuator materials have the ability to change the shape, stiffness, position, natural frequency, damping and/or other mechanical characteristics of the smart material systems in response to changes in temperature, electric field and/or magnetic field.

    Silicon Rubber
  • Switch Configuration
    OFF (ON)
  • Actuator Style
    Round Button
  • Contact Materials
    Stainless Steel
  • Pole Throw Configuration
    SPST
  • Mounting
    Surface Mount
  • Body Orientation
    Straight
  • Product Depth (mm)
    4.2(mm)
  • Actuator Length (mm)
    0.8(mm)
  • Operating Temp Range
    -40C to 85C
  • Mounting Styles
    Surface Mount
  • ActuatorColor
    Red
  • Voltage Rating (VDC)
    32(V)
  • Switch Function Configuration
    OFF ON
  • Seal
    No
  • Dimensions
    6 x 4 x 2.5mm
  • Voltage, Rating
    32V dc
  • Maximum Operating Temperature

    the maximum body temperature at which the thermistor is designed to operate for extended periods of time with acceptable stability of its electrical characteristics.

    +85°C
  • Minimum Operating Temperature
    -40°C
  • Illuminated
    Yes
  • Package
    Tape & Reel (TR);Cut Tape (CT);
  • Base Product Number
    1825086
  • Mfr
    TE Connectivity ALCOSWITCH Switches
  • Product Status
    Active
  • Rohs Code
    Yes
  • Manufacturer Part Number
    1825086-2
  • Manufacturer
    TE Connectivity
  • Part Life Cycle Code
    Active
  • Ihs Manufacturer
    TE CONNECTIVITY LTD
  • Risk Rank
    1.75
  • Manufacturer Series
    1825086
  • Operating Temperature

    The operating temperature is the range of ambient temperature within which a power supply, or any other electrical equipment, operate in. This ranges from a minimum operating temperature, to a peak or maximum operating temperature, outside which, the power supply may fail.

    -40 to 85 °C
  • Series
    FSMJM
  • Packaging

    Semiconductor package is a carrier / shell used to contain and cover one or more semiconductor components or integrated circuits. The material of the shell can be metal, plastic, glass or ceramic.

    Tape & Reel (TR)
  • Part Status

    Parts can have many statuses as they progress through the configuration, analysis, review, and approval stages.

    Active
  • ECCN Code
    EAR99
  • Subcategory
    Switches
  • Ingress Protection

    Ingress Protection rating (or just IP rating), is an international standard (IEC 60529) used to rate the degree of protection or sealing effectiveness in electrical enclosures against intrusion of objects, water, dust or accidental contact. It corresponds to the European standard EN 60529.

    --
  • Reach Compliance Code
    compliant
  • Termination Style
    Gull Wing
  • Actuator Type
    Standard
  • Brand Name
    Alcoswitch
  • Circuit
    SPST-NO
  • Switch Function

    This function will evaluate a given expression (or a value) against a list of values and will return a result corresponding to the first matching value. In case there is no matching value, an optional default value will be returned.

    Off-Mom
  • Illumination Voltage (Nominal)
    --
  • Illumination Type, Color
    --
  • Illumination
    Non-Illuminated
  • Mechanical Life
    100000 Cycles
  • Switch Type

    Based on their characteristics, there are basically three types of switches: Linear switches, tactile switches and clicky switches.

    PUSHBUTTON SWITCH
  • Contact Current Rating

    The current rating of a contact is defined as the current level that creates a certain temperature rise of the contact spring — usually 20°C or 30°C. Both electrical and thermal factors govern the heat created by the current.

    50 mA
  • Operating Force
    2.55 N
  • Illumination Type
    Not Required
  • Terminal Type

    Terminal type or emulation specifies how your computer and the host computer to which you are connected exchange information.

    Gull Wing
  • Product Type

    a group of products which fulfill a similar need for a market segment or market as a whole.

    Tactile Switches
  • Operating Temperature Range

    An operating temperature is the allowable temperature range of the local ambient environment at which an electrical or mechanical device operates. The device will operate effectively within a specified temperature range which varies based on the device function and application context, and ranges from the minimum operating temperature to the maximum operating temperature (or peak operating temperature).

    -40 → +85°C
  • Illumination Color
    -
  • Actuator Orientation

    A valve actuator is the mechanism for opening and closing a valve. Manually operated valves require someone in attendance to adjust them using a direct or geared mechanism attached to the valve stem. Power-operated actuators, using gas pressure, hydraulic pressure or electricity, allow a valve to be adjusted remotely, or allow rapid operation of large valves. Power-operated valve actuators may be the final elements of an automatic control loop which automatically regulates some flow, level or other process. Actuators may be only to open and close the valve, or may allow intermediate positioning; some valve actuators include switches or other ways to remotely indicate the position of the valve.

    Top Actuated
  • Outline
    6.00mm x 4.00mm
  • Contact Rating @ Voltage
    0.05A @ 32VDC
  • Current Rating (Max)
    0.05(A)
  • Switch Travel
    0.50mm
  • Actuator Height off PCB, Vertical
    2.50mm
  • Contact Configuration
    SPST
  • Lamp Type

    The different types of lamps include:Incandescent Lamps,Tungsten Halogen Lamps,Fluorescent Lamps,Compact Fluorescent Lamps,Mercury Vapour Lamps,Metal Halide Lamps,High Pressure Sodium Vapour Lamps,Low Pressure Sodium Vapour Lamps.

    -
  • Features
    --
  • IP Rating

    IP (or "Ingress Protection") ratings are defined in international standard EN 6529 (British BS EN 6529:1992, European IEC 659:1989). They are?used to define levels of sealing effectiveness of electrical enclosures against intrusion from foreign bodies?(tools, dirt etc) and moisture.

    IP67
  • Product Length (mm)
    7.3(mm)
  • Width
    4mm
  • Height
    2.5mm
  • Length
    6mm
  • Actuator Length
    0.8mm
  • Actuator Length, Right Angle
    --
  • Product Height (mm)
    2.5(mm)
0 Similar Products Remaining