I3A4W008A033V-001-R

TDK-Lambda Americas Inc. I3A4W008A033V-001-R

Part No:

I3A4W008A033V-001-R

Package:

Module

ROHS:

AINNX NO:

3696271-I3A4W008A033V-001-R

Description:

DC DC CONVERTER 3.3-16.5V

Products specifications
  • Factory Lead Time
    22 Weeks
  • Mounting Type
    Surface Mount
  • Package / Case
    Module
  • Operating Temperature

    The operating temperature is the range of ambient temperature within which a power supply, or any other electrical equipment, operate in. This ranges from a minimum operating temperature, to a peak or maximum operating temperature, outside which, the power supply may fail.

    -40°C~125°C
  • Series
    i3A (100W)
  • Published
    2017
  • Size / Dimension
    0.92Lx0.75W x 0.38 H 23.4mmx19.1mmx9.6mm
  • Part Status

    Parts can have many statuses as they progress through the configuration, analysis, review, and approval stages.

    Active
  • Moisture Sensitivity Level (MSL)
    1 (Unlimited)
  • Type
    Non-Isolated PoL Module
  • Applications
    ITE (Commercial)
  • Power (Watts)
    128W
  • Peak Reflow Temperature (Cel)
    NOT SPECIFIED
  • Time@Peak Reflow Temperature-Max (s)
    NOT SPECIFIED
  • Number of Outputs
    1
  • Efficiency
    96.5%
  • Voltage - Input (Max)
    53V
  • Output Voltage
    16.5V
  • Voltage - Input (Min)
    9V
  • Output Power

    That power available at a specified output of a device under specified conditions of operation.

    100W
  • Height
    9.6mm
  • RoHS Status

    RoHS means “Restriction of Certain Hazardous Substances” in the “Hazardous Substances Directive” in electrical and electronic equipment.

    RoHS Compliant
0 Similar Products Remaining
Documents & Media Download datasheets and manufacturer documentation for TDK-Lambda Americas Inc. I3A4W008A033V-001-R.