Description:

TDK LAMBDA DPP50-15 AC/DC DIN Rail Power Supply, Class II, Adjustable, Fixed, 1 Output, 85 VAC, 264 VAC, 50 W, 15 VDC

Products specifications
  • Factory Lead Time
    20 Weeks
  • Mount
    DIN Rail
  • Mounting Type
    DIN Rail
  • Number of Pins
    7
  • Weight
    259.999997g
  • Voltage Rated

    RATED voltage is the voltage on the nameplate - the "design point" for maximum power throughput and safe thermal operation.

    15V
  • Usage Level
    Commercial grade
  • Operating Temperature

    The operating temperature is the range of ambient temperature within which a power supply, or any other electrical equipment, operate in. This ranges from a minimum operating temperature, to a peak or maximum operating temperature, outside which, the power supply may fail.

    -10°C~71°C With Derating
  • Series
    DPP (15-100W)
  • Published
    2008
  • Size / Dimension
    3.58Lx1.77W x 2.95 H 90.9mmx45.0mmx74.9mm
  • Part Status

    Parts can have many statuses as they progress through the configuration, analysis, review, and approval stages.

    Active
  • Moisture Sensitivity Level (MSL)
    Not Applicable
  • Number of Terminations
    7
  • Type
    Enclosed
  • Applications
    ITE (Commercial)
  • Power Rating
    50W
  • Voltage - Rated DC
    15V
  • Max Power Dissipation

    The maximum power that the MOSFET can dissipate continuously under the specified thermal conditions.

    50W
  • Terminal Position
    UNSPECIFIED
  • Terminal Form

    Occurring at or forming the end of a series, succession, or the like; closing; concluding.

    UNSPECIFIED
  • Number of Functions
    1
  • Depth
    91mm
  • Current Rating

    Current rating is the maximum current that a fuse will carry for an indefinite period without too much deterioration of the fuse element.

    3.4A
  • Frequency
    63Hz
  • Number of Outputs
    1
  • Approval Agency
    CE
  • Efficiency
    85%
  • Voltage - Isolation
    3kV
  • Output Voltage
    15V
  • Max Output Current

    The maximum current that can be supplied to the load.

    3.4A
  • Input Voltage-Nom
    115V
  • Trim/Adjustable Output
    YES
  • Max Voltage Rating (AC)
    264V
  • Max Current Rating
    1.35A
  • Output Current

    The rated output current is the maximum load current that a power supply can provide at a specified ambient temperature. A power supply can never provide more current that it's rated output current unless there is a fault, such as short circuit at the load.

    3.4A
  • Output Power

    That power available at a specified output of a device under specified conditions of operation.

    50W
  • Protections
    OUTPUT OVER CURRENT; OUTPUT OVER VOLTAGE
  • Min Input Voltage
    85V
  • Max Input Voltage
    264V
  • Current - Output 1
    3.4A
  • Max Output Power

    The maximum output power = the maximum output current × the rated output voltage

    50W
  • Nominal Output Voltage
    15V
  • Min Input Voltage (AC)
    85V
  • Max Input Voltage (AC)
    264V
  • Features
    Adjustable Output, DC Input Capable, Load Sharing, Universal Input
  • Height
    75mm
  • Width
    45mm
  • REACH SVHC
    Unknown
  • Radiation Hardening

    Radiation hardening is the process of making electronic components and circuits resistant to damage or malfunction caused by high levels of ionizing radiation, especially for environments in outer space (especially beyond the low Earth orbit), around nuclear reactors and particle accelerators, or during nuclear accidents or nuclear warfare.

    No
  • RoHS Status

    RoHS means “Restriction of Certain Hazardous Substances” in the “Hazardous Substances Directive” in electrical and electronic equipment.

    RoHS Compliant
0 Similar Products Remaining
Documents & Media Download datasheets and manufacturer documentation for TDK-Lambda Americas Inc. DPP50-15.