IPB48003A150V-001-R

TDK IPB48003A150V-001-R

Part No:

IPB48003A150V-001-R

Manufacturer:

TDK

Datasheet:

-

Package:

TO-220-3

AINNX NO:

46162720-IPB48003A150V-001-R

Description:

Module DC-DC 1-OUT 15V 2.75A 41W 6-Pin Brick

Products specifications
  • Mounting Type
    Through Hole
  • Package / Case
    TO-220-3
  • Number of Pins
    6
  • Supplier Device Package
    TO-220-3
  • Package
    Bulk
  • Mfr
    Sanken
  • Product Status
    Obsolete
  • Voltage-Off State
    600 V
  • Voltage-Output 1
    15 V
  • RoHS
    Compliant
  • Package Description
    ,
  • Operating Temperature-Min
    -40 °C
  • Reflow Temperature-Max (s)
    NOT SPECIFIED
  • Operating Temperature-Max
    125 °C
  • Rohs Code
    Yes
  • Input Voltage-Max
    75 V
  • Manufacturer Part Number
    IPB48003A150V-001-R
  • Approvals
    CB, CE, UL, VDE
  • Manufacturer
    TDK-Lambda Corporation
  • Part Life Cycle Code
    Obsolete
  • Input Voltage-Min
    36 V
  • Ihs Manufacturer
    TDK-LAMBDA CORP
  • Output Voltage-Nom
    15 V
  • Risk Rank
    5.84
  • Operating Temperature

    The operating temperature is the range of ambient temperature within which a power supply, or any other electrical equipment, operate in. This ranges from a minimum operating temperature, to a peak or maximum operating temperature, outside which, the power supply may fail.

    -40°C ~ 125°C (TJ)
  • Series
    -
  • Additional Feature

    Any Feature, including a modified Existing Feature, that is not an Existing Feature.

    REMOTE SHUTDOWN
  • Subcategory
    Power Supply Modules
  • Peak Reflow Temperature (Cel)
    NOT SPECIFIED
  • Reach Compliance Code
    compliant
  • Number of Outputs
    1
  • Output Voltage
    15 V
  • Configuration
    Single
  • Analog IC - Other Type
    DC-DC REGULATED POWER SUPPLY MODULE
  • Output Current

    The rated output current is the maximum load current that a power supply can provide at a specified ambient temperature. A power supply can never provide more current that it's rated output current unless there is a fault, such as short circuit at the load.

    2.75 A
  • Output Power

    That power available at a specified output of a device under specified conditions of operation.

    45 W
  • Output Current-Max
    2.75 A
  • Current - Output 1
    3 A
  • Total Power Output-Max
    41 W
  • Nominal Input Voltage

    The actual voltage at which a circuit operates can vary from the nominal voltage within a range that permits satisfactory operation of equipment. The word “nominal” means “named”.

    48 V
  • Voltage - Gate Trigger (Vgt) (Max)
    1.5 V
  • Current - Non Rep. Surge 50, 60Hz (Itsm)
    30A, 32A
  • Current - Gate Trigger (Igt) (Max)
    20 mA
  • Isolation Voltage

    Isolation voltage refers to a test of the ability of an insulator to minimize the flow of electric current with a high applied voltage.

    1.5 kV
  • Current - On State (It (RMS)) (Max)
    3 A
  • Triac Type
    Standard
  • Ripple Voltage (Main Out)
    0.03535 Vrms
  • Efficiency (Main Output)
    87%
  • Width
    70.104 mm
  • Height
    123.952 mm
  • Length
    350.012 mm
  • Radiation Hardening

    Radiation hardening is the process of making electronic components and circuits resistant to damage or malfunction caused by high levels of ionizing radiation, especially for environments in outer space (especially beyond the low Earth orbit), around nuclear reactors and particle accelerators, or during nuclear accidents or nuclear warfare.

    No
0 Similar Products Remaining