WW3JB130R

StackpoleElectronics WW3JB130R

Part No:

WW3JB130R

Datasheet:

-

Package:

Axial

AINNX NO:

26035752-WW3JB130R

Description:

Products specifications
  • Package / Case
    Axial
  • Supplier Device Package
    Axial
  • Package
    Bulk
  • Mfr
    Stackpole Electronics Inc
  • Product Status
    Active
  • Maximum Operating Temperature

    the maximum body temperature at which the thermistor is designed to operate for extended periods of time with acceptable stability of its electrical characteristics.

    + 350 C
  • Minimum Operating Temperature
    - 55 C
  • Series
    WW
  • Operating Temperature

    The operating temperature is the range of ambient temperature within which a power supply, or any other electrical equipment, operate in. This ranges from a minimum operating temperature, to a peak or maximum operating temperature, outside which, the power supply may fail.

    -55°C ~ 350°C
  • Size / Dimension
    0.187 Dia x 0.560 L (4.75mm x 14.22mm)
  • Tolerance
    ±5%
  • Number of Terminations
    2
  • Temperature Coefficient

    The resistance-change factor per degree Celsius of temperature change is called the temperature coefficient of resistance. This factor is represented by the Greek lower-case letter “alpha” (α). A positive coefficient for a material means that its resistance increases with an increase in temperature.

    ±20ppm/°C
  • Resistance
    130
  • Composition
    Wirewound
  • Applications
    High Power
  • Power (Watts)
    3W
  • Power Rating
    3 W
  • Termination Style
    Axial
  • Failure Rate

    the frequency with which an engineered system or component fails, expressed in failures per unit of time. It is usually denoted by the Greek letter λ (lambda) and is often used in reliability engineering.

    -
  • Features
    Moisture Resistant
  • Height Seated (Max)
    -
  • Length
    14.22 mm
  • Diameter
    4.75 mm