Material
Aluminum
Shape
Square, Fins
Package Cooled
Assorted (BGA, LGA, CPU, ASIC...)
Material Finish
Blue Anodized
Conductor Material
A conductor is a material which contains movable electric charges. In metallic conductors, such as copper or aluminum, the movable charged particles are electrons, though in other cases they can be ions or other positively charged species.
-
Jacket (Insulation) Material
Poly-Vinyl Chloride (PVC)
Shield Material
Aluminum; Copper, Tinned
Package
Bulk
Mfr
Siemens
Product Status
Active
Cable Types
Multi-Pair, Cat6a
Stranding element
Pairs
Flame retardant
No
Permitted cable outer temperature after assembling without vibration
-40 - 85
Diameter conductor
0.51
Material core insulation
Other
Conductor surface
Bare
Colour outer sheath
Green
Permitted cable outer temperature during assembling/handling
-40 - 80
Outer diameter approx.
8
Specification material outer sheath
Other
Screen over stranding element
None
Category
6
Protective sheath
No
Core identification
Colour
Number of stranding elements
4
Min. permitted bending radius, moving application with forced guidance
40
Screen over stranding
Foil + braiding
Low smoke (according to EN 61034-2)
No
NVP value
67
Min. permitted bending radius, moving application/free movement
40
Min. permitted bending radius, stationary application/permanent installation
40
Material outer sheath
Polyvinyl chloride (PVC)
Series
pushPIN™
Operating Temperature
The operating temperature is the range of ambient temperature within which a power supply, or any other electrical equipment, operate in. This ranges from a minimum operating temperature, to a peak or maximum operating temperature, outside which, the power supply may fail.
-40°C ~ 85°C
Part Status
Parts can have many statuses as they progress through the configuration, analysis, review, and approval stages.
Active
Type
Top Mount
Number of Conductors
8 (4 Pair Twisted)
Wire Gauge
a measurement of?wire?diameter.?This determines the amount of electric current the wire can safely carry, as well as its electrical resistance and weight.
24 AWG
Voltage
80 V
Attachment Method
Push Pin
Height Off Base (Height of Fin)
1.181 (30.00mm)
Thermal Resistance @ Forced Air Flow
7.40°C/W @ 100 LFM
Jacket Color
Green
Conductor Strand
Stranded conductors are composed of uninsulated “strands” of wire twisted together. The advantages of conductor stranding over a single strand of equal cross-section are increased flexibility and flex-fatigue life.
-
Usage
-
Jacket (Insulation) Diameter
0.315 (8.00mm)
Conductor Insulation
Polyethylene (PE)
Shield Type
Foil, Braid
Shield Coverage
100%
Stranding
Bundle
Thermal Resistance @ Natural
--
Power Dissipation @ Temperature Rise
--
Features
-
Width
1.575 (40.00mm)
Length
1.575 (40.00mm)
Diameter
--
Jacket (Insulation) Thickness
-
Ratings
-