3RQ30702SB30

Siemens 3RQ30702SB30

Part No:

3RQ30702SB30

Manufacturer:

Siemens

Datasheet:

-

Package:

-

AINNX NO:

28535508-3RQ30702SB30

Description:

OUT CPLR W/SS OUT,24VAC/DC, .5A

Products specifications
  • Mounting Type
    DIN Rail
  • Mfr
    Siemens
  • Package
    Box
  • Product Status
    Active
  • Contact Materials
    -
  • Base Product Number
    3RQ3070
  • Dim
    (W x H x D) 6.2 x 93 x 72.5 mm
  • RoHS-compliant
    Yes
  • Connections
    Spring-loaded connector
  • Fall time
    4ms
  • Number of contacts as normally open contact
    1
  • Switching voltage (max.)
    30V DC
  • Min. temperature
    -25°C
  • Content
    5pc(s)
  • Max. temperature
    +60°C
  • Rated control supply voltage at AC 50 Hz
    11 - 30
  • Number of contacts as change-over contact
    0
  • Rated control supply voltage at AC 60 Hz
    11 - 30
  • Degree of protection (IP)
    IP20
  • Voltage type for actuating
    AC/DC
  • Number of contacts as normally closed contact
    0
  • Rated control supply voltage at DC
    11 - 30
  • With detachable clamps
    No
  • Series
    SIRIUS 3RQ3
  • Operating Temperature

    The operating temperature is the range of ambient temperature within which a power supply, or any other electrical equipment, operate in. This ranges from a minimum operating temperature, to a peak or maximum operating temperature, outside which, the power supply may fail.

    -25°C ~ 60°C
  • Type
    3RQ3070-2SB30
  • Depth
    72.5mm
  • Termination Style
    Spring Terminal
  • Contact Form

    A page on a website that allows users to communicate with the site owner. The page has fields for filling in name, address and type of comment. On most company websites, email and mailing addresses are also included; however, the contact form provides an immediate, convenient way for users to ask the company questions.

    SPST-NO (1 Form A)
  • Relay Type
    General Purpose
  • Operate Time

    The time interval between the instant of the occurrence of a specified input condition to a system and the instant of completion of a specified operation.

    2 ms
  • Coil Voltage
    24VAC/DC
  • Coil Type

    There are 2 different types of 'coil'; one has copper on it (IUD) and the other contains hormone (Mirena IUS). Both are over 99% effective at protecting against pregnancy.

    Non Latching
  • Switching Voltage

    The maximum switching voltage of a relay is the maximum voltage that can be across the contacts whether the relay is open or closed. Operating a relay with high voltages present can cause arcing, and this in turn erodes the contacts and eventually degrades contact performance.

    30VDC - Max
  • Release Time

    In telecommunication, release time is the time interval for a circuit to respond when an enabling signal is discontinued

    4 ms
  • Must Operate Voltage
    -
  • Contact Rating (Current)
    500 mA
  • Must Release Voltage
    -
  • Seal Rating
    -
  • Coil Insulation
    -
  • Features
    Lighted Indicator
  • Width
    6.2
  • Height
    93mm
  • Length
    93mm
0 Similar Products Remaining