3RQ30652SM30

Siemens 3RQ30652SM30

Part No:

3RQ30652SM30

Manufacturer:

Siemens

Datasheet:

-

Package:

-

AINNX NO:

28518762-3RQ30652SM30

Description:

RELAY GEN PURPOSE SPST 5A 24V

Products specifications
  • Mounting Type
    DIN Rail
  • Mfr
    Siemens
  • Package
    Box
  • Product Status
    Active
  • Contact Materials
    -
  • Base Product Number
    3RQ3065
  • Dim
    (W x H x D) 6.2 x 93 x 75 mm
  • RoHS-compliant
    Yes
  • Connections
    Spring-loaded connector
  • Fall time
    0.3ms
  • Number of contacts as normally open contact
    1
  • Switching voltage (max.)
    30V DC
  • Min. temperature
    -25°C
  • Content
    5pc(s)
  • Max. temperature
    +60°C
  • Dimensions
    6.2 x 93 x 75mm
  • Maximum Operating Temperature

    the maximum body temperature at which the thermistor is designed to operate for extended periods of time with acceptable stability of its electrical characteristics.

    +60°C
  • Series
    SIRIUS 3RQ3
  • Operating Temperature

    The operating temperature is the range of ambient temperature within which a power supply, or any other electrical equipment, operate in. This ranges from a minimum operating temperature, to a peak or maximum operating temperature, outside which, the power supply may fail.

    -25°C ~ 60°C
  • Type
    3RQ3065-2SM30
  • Depth
    75mm
  • Termination Style
    Spring Terminal
  • Contact Form

    A page on a website that allows users to communicate with the site owner. The page has fields for filling in name, address and type of comment. On most company websites, email and mailing addresses are also included; however, the contact form provides an immediate, convenient way for users to ask the company questions.

    SPST-NO (1 Form A)
  • Relay Type
    General Purpose
  • Operating Temperature Range

    An operating temperature is the allowable temperature range of the local ambient environment at which an electrical or mechanical device operates. The device will operate effectively within a specified temperature range which varies based on the device function and application context, and ranges from the minimum operating temperature to the maximum operating temperature (or peak operating temperature).

    -25 → +60°C
  • Operate Time

    The time interval between the instant of the occurrence of a specified input condition to a system and the instant of completion of a specified operation.

    0.2 ms
  • Coil Voltage
    24VDC
  • Coil Type

    There are 2 different types of 'coil'; one has copper on it (IUD) and the other contains hormone (Mirena IUS). Both are over 99% effective at protecting against pregnancy.

    Non Latching
  • Switching Voltage

    The maximum switching voltage of a relay is the maximum voltage that can be across the contacts whether the relay is open or closed. Operating a relay with high voltages present can cause arcing, and this in turn erodes the contacts and eventually degrades contact performance.

    30VDC - Max
  • Release Time

    In telecommunication, release time is the time interval for a circuit to respond when an enabling signal is discontinued

    0.3 ms
  • Must Operate Voltage
    -
  • Contact Rating (Current)
    5 A
  • Must Release Voltage
    -
  • Input Current
    5A
  • Seal Rating
    -
  • Coil Insulation
    -
  • Features
    Lighted Indicator
  • Width
    6.2
  • Height
    93mm
  • Length
    93mm