MP240D3

Sensata MP240D3

Part No:

MP240D3

Manufacturer:

Sensata

Datasheet:

-

Package:

-

AINNX NO:

70157081-MP240D3

Category:

Accessories

Description:

MP Series 3 A 280 V Zero Cross DC Control Solid State Relay Through Hole - SIP-4

Products specifications
  • Mount
    PCB, Through Hole
  • Number of Pins
    4
  • Approvals
    CE, CSA, UL, VDE
  • Case/Package
    SIP
  • CoilResistance
    1.5 kΩ
  • Data Polarity
    DC
  • Max Length
    44 mm
  • Number of Elements
    1
  • RoHS
    Compliant
  • Voltage, Rating
    280 V
  • Termination
    PC Pin
  • Max Operating Temperature

    The Maximum Operating Temperature is the maximum body temperature at which the thermistor is designed to operate for extended periods of time with acceptable stability of its electrical characteristics.

    80 °C
  • Min Operating Temperature
    -40 °C
  • Depth
    10.2 mm
  • Current Rating

    Current rating is the maximum current that a fuse will carry for an indefinite period without too much deterioration of the fuse element.

    3 A
  • Output Voltage
    280 V
  • Max Output Current

    The maximum current that can be supplied to the load.

    3 A
  • Operating Supply Voltage

    The voltage level by which an electrical system is designated and to which certain operating characteristics of the system are related.

    280 V
  • Output Current

    The rated output current is the maximum load current that a power supply can provide at a specified ambient temperature. A power supply can never provide more current that it's rated output current unless there is a fault, such as short circuit at the load.

    3 A
  • Throw Configuration
    SPST
  • Max Output Voltage

    The maximum output voltage refers to the dynamic area beyond which the output is saturated in the positive or negative direction, and is limited according to the load resistance value.

    280 V
  • Max Surge Current

    Surge current is a peak non repetitive current. Maximum (peak or surge) forward current = IFSM or if(surge), the maximum peak amount of current the diode is able to conduct in forward bias mode.

    90 A
  • Relay Type
    Relay
  • Switching Voltage

    The maximum switching voltage of a relay is the maximum voltage that can be across the contacts whether the relay is open or closed. Operating a relay with high voltages present can cause arcing, and this in turn erodes the contacts and eventually degrades contact performance.

    280 V
  • Input Current
    2.6 mA
  • Load Current

    The Load Current can be defined as 1) Full load current the maximum current that an electrical machine can operate; 2) Rated Current the current rated on the nameplate of an electrical machine; 3) Nominal Current is generally mentioned in the specification documents that is normally the same value as the rated one.

    3 A
  • Isolation Voltage

    Isolation voltage refers to a test of the ability of an insulator to minimize the flow of electric current with a high applied voltage.

    4 kV
  • Switching Current
    3 A
  • Height
    25 mm
  • Length
    43.1 mm
  • Radiation Hardening

    Radiation hardening is the process of making electronic components and circuits resistant to damage or malfunction caused by high levels of ionizing radiation, especially for environments in outer space (especially beyond the low Earth orbit), around nuclear reactors and particle accelerators, or during nuclear accidents or nuclear warfare.

    No
  • REACH SVHC
    Yes
  • Lead Free
    Lead Free
0 Similar Products Remaining