REG96PUN2LRHU

Schneider Electric REG96PUN2LRHU

Part No:

REG96PUN2LRHU

Manufacturer:

Schneider Electric

Datasheet:

-

Package:

-

AINNX NO:

24372978-REG96PUN2LRHU

Description:

Products specifications
  • Mounting Type
    DIN Rail
  • Mount
    Panel
  • Weight
    -
  • Package
    Box
  • Mfr
    Schneider Electric
  • Product Status
    Obsolete
  • RoHS
    Compliant
  • Operating Temperature

    The operating temperature is the range of ambient temperature within which a power supply, or any other electrical equipment, operate in. This ranges from a minimum operating temperature, to a peak or maximum operating temperature, outside which, the power supply may fail.

    -20°C ~ 60°C
  • Series
    Zelio Control
  • Termination
    Screw
  • Type
    Temperature Controller (RTD, Type B, E, J, K, L, N, PLII, R, S, T)
  • Max Operating Temperature

    The Maximum Operating Temperature is the maximum body temperature at which the thermistor is designed to operate for extended periods of time with acceptable stability of its electrical characteristics.

    50 °C
  • Min Operating Temperature
    -10 °C
  • Voltage - Supply
    100 ~ 240VAC
  • Ingress Protection

    Ingress Protection rating (or just IP rating), is an international standard (IEC 60529) used to rate the degree of protection or sealing effectiveness in electrical enclosures against intrusion of objects, water, dust or accidental contact. It corresponds to the European standard EN 60529.

    IP20, IP66 - Dust Tight, Water Resistant
  • Termination Style
    -
  • Number of Outputs
    2
  • Output Voltage
    220 V
  • Output Type
    Relay, Solid State
  • Panel Cutout Dimensions
    Rectangular - 92.80mm x 45.80mm
  • Max Supply Voltage

    In general, the absolute maximum common-mode voltage is VEE-0.3V and VCC+0.3V, but for products without a protection element at the VCC side, voltages up to the absolute maximum rated supply voltage (i.e. VEE+36V) can be supplied, regardless of supply voltage.

    240 V
  • Min Supply Voltage

    The minimum supply voltage (V min ) is explored for sequential logic circuits by statistically simulating the impact of within-die process variations and gate-dielectric soft breakdown on data retention and hold time.

    100 V
  • Number of Inputs
    1
  • Min Output Voltage
    30 V
  • Display Type
    LCD - Dual Color Characters
  • Input Range

    The input range of a channel determines how large signals can be measured. The input range is defined as full scale value, the highest voltage that can be measured, both in positive as in negative direction.

    0 ~ 20mA, 0 ~ 10VDC
  • Number of Characters Per Row
    4
  • Control Method
    Proportional (PID)
  • Communications
    RS-485
  • Features
    -
  • Display Characters - Height
    -
  • REACH SVHC
    Unknown
  • Ratings
    IP20, IP66
0 Similar Products Remaining