XPSMCMRO0004G

Schneider XPSMCMRO0004G

Part No:

XPSMCMRO0004G

Manufacturer:

Schneider

Datasheet:

-

Package:

-

AINNX NO:

49895142-XPSMCMRO0004G

Category:

Safety Relays

Description:

XPSMCM Output expansion units. 4 relay outputs with cage clamp teminal.

Products specifications
  • Mounting Type
    DIN Rail
  • Package
    Box
  • Mfr
    Schneider Electric
  • Product Status
    Active
  • Contact Materials
    -
  • Number of I/Os
    12
  • Range
    Preventa
  • Type of electric connection
    Spring clamp connection
  • SIL according to IEC 61508
    3
  • Voltage type for actuating
    DC
  • Rail mounting possible
    Yes
  • Rated control supply voltage at DC
    24 - 24
  • With detachable clamps
    Yes
  • Model
    Expansion device
  • Factory Pack QuantityFactory Pack Quantity
    1
  • Manufacturer
    Schneider Electric
  • Brand
    Schneider Electric
  • Operating Temperature

    The operating temperature is the range of ambient temperature within which a power supply, or any other electrical equipment, operate in. This ranges from a minimum operating temperature, to a peak or maximum operating temperature, outside which, the power supply may fail.

    -10°C ~ 55°C
  • Series
    Modicon MCM
  • Subcategory
    Controllers
  • Supply Voltage
    24 V dc
  • Depth
    114.5
  • Termination Style
    Spring Terminal
  • Contact Form

    A page on a website that allows users to communicate with the site owner. The page has fields for filling in name, address and type of comment. On most company websites, email and mailing addresses are also included; however, the contact form provides an immediate, convenient way for users to ask the company questions.

    4PST-NO (4 Form A)
  • Product Type

    a group of products which fulfill a similar need for a market segment or market as a whole.

    Controllers
  • Coil Voltage
    24VDC
  • Switching Voltage

    The maximum switching voltage of a relay is the maximum voltage that can be across the contacts whether the relay is open or closed. Operating a relay with high voltages present can cause arcing, and this in turn erodes the contacts and eventually degrades contact performance.

    400VAC, 250VDC - Max
  • Must Operate Voltage
    -
  • Contact Rating (Current)
    6 A
  • Display Type
    LED
  • Coil Power
    -
  • Must Release Voltage
    -
  • Features
    Lighted Indicator
  • Product Category

    a particular group of related products.

    Schneider Electric
  • Width
    22.5
  • Height
    99
0 Similar Products Remaining