FN7512-63-M6

Schaffner EMC Inc. FN7512-63-M6

Part No:

FN7512-63-M6

Manufacturer:

Schaffner EMC Inc.

Datasheet:

FN751x Series

Package:

Axial - Threaded Terminals

ROHS:

AINNX NO:

854389-FN7512-63-M6

Description:

CAP FEEDTHRU 0.1UF 20% 1KV AXIAL

Products specifications
  • Factory Lead Time
    10 Weeks
  • Mount
    Through Hole
  • Package / Case
    Axial - Threaded Terminals
  • Operating Temperature

    The operating temperature is the range of ambient temperature within which a power supply, or any other electrical equipment, operate in. This ranges from a minimum operating temperature, to a peak or maximum operating temperature, outside which, the power supply may fail.

    -40°C~100°C
  • Packaging

    Semiconductor package is a carrier / shell used to contain and cover one or more semiconductor components or integrated circuits. The material of the shell can be metal, plastic, glass or ceramic.

    Tray
  • Series
    FN 751X
  • Published
    2009
  • Size / Dimension
    0.984Diax3.780L 25.00mmx96.00mm
  • Tolerance
    ±20%
  • Pbfree Code
    yes
  • Part Status

    Parts can have many statuses as they progress through the configuration, analysis, review, and approval stages.

    Active
  • Moisture Sensitivity Level (MSL)
    1 (Unlimited)
  • Termination
    Screw
  • Capacitance
    0.1μF
  • Voltage - Rated DC
    250V
  • Current Rating

    Current rating is the maximum current that a fuse will carry for an indefinite period without too much deterioration of the fuse element.

    63A
  • Voltage - Rated AC
    250V
  • Approval Agency
    UL; ENEC-14
  • Physical Dimension
    D25.0XH30.0 (mm)/D0.984XH1.181 (inch)
  • Operating Frequency

    Operating frequency is the frequency at which the communications are being made with the total bandwidth occupied by the carrier signal with modulation. Usually bandwidth of the antenna will be wider than the bandwidth of the signal so that more than one center frequency the antenna can be put in to effective use.

    50/60Hz Hz
  • Ripple Current

    the pulsed current consumption of non-linear devices like capacitor-input rectifiers.

    63A
  • Filter Type
    AC FEED THROUGH CAPACITOR
  • Thread Size

    given in nominal sizes, not in the actual measurement.

    M16x1
  • DC Resistance (DCR) (Max)
    0.3mOhm Typ
  • Rated Voltage
    300V
  • Leakage Current (Max)
    9.4mA
  • Insulation Resistance-Min
    1500MOhm
  • High Pot
    3000 V
  • Diameter
    25mm
  • Height
    30mm
  • REACH SVHC
    No SVHC
  • Radiation Hardening

    Radiation hardening is the process of making electronic components and circuits resistant to damage or malfunction caused by high levels of ionizing radiation, especially for environments in outer space (especially beyond the low Earth orbit), around nuclear reactors and particle accelerators, or during nuclear accidents or nuclear warfare.

    No
  • RoHS Status

    RoHS means “Restriction of Certain Hazardous Substances” in the “Hazardous Substances Directive” in electrical and electronic equipment.

    RoHS Compliant
  • Ratings
    Y2