2910124

Phoenix Contact 2910124

Part No:

2910124

Manufacturer:

Phoenix Contact

Datasheet:

-

Package:

-

AINNX NO:

44418528-2910124

Description:

QUINT4-PS/12DC/24DC/5/PT

Products specifications
  • Mount
    Surface Mount
  • Mounting Type
    DIN Rail Mount
  • RoHS
    Compliant
  • Package
    Bulk
  • Voltage - Output 5
    -
  • Voltage-Output 1
    24V
  • Voltage - Output 6
    -
  • Mfr
    Phoenix Contact
  • Product Status
    Active
  • Standard Number
    60601-1
  • Input Voltage Range
    12 V dc
  • Isolated
    Yes
  • Mounting Styles
    DIN Rail
  • Input Voltage-Max
    16.8 V
  • Input Voltage-Min
    9 V
  • Operating Temperature

    The operating temperature is the range of ambient temperature within which a power supply, or any other electrical equipment, operate in. This ranges from a minimum operating temperature, to a peak or maximum operating temperature, outside which, the power supply may fail.

    -25°C ~ 70°C
  • Series
    Quint
  • Size / Dimension
    4.92 L x 1.42 W x 5.12 H (125.0mm x 36.0mm x 130.0mm)
  • Tolerance
    10 %
  • Max Operating Temperature

    The Maximum Operating Temperature is the maximum body temperature at which the thermistor is designed to operate for extended periods of time with acceptable stability of its electrical characteristics.

    125 °C
  • Min Operating Temperature
    -55 °C
  • Applications
    Medical
  • Power (Watts)
    150W
  • Capacitance
    10 pF
  • Subcategory
    DC-DC Converter
  • Depth
    1.25 mm
  • Number of Outputs
    1
  • Approval Agency
    SIQ, UL
  • Efficiency
    91.3%
  • Voltage - Isolation
    2 kV
  • Output Voltage
    24V dc
  • Current - Output (Max)
    5A
  • Input Type
    DC
  • Output Power

    That power available at a specified output of a device under specified conditions of operation.

    120 W
  • Voltage - Output 2
    -
  • Product Type

    a group of products which fulfill a similar need for a market segment or market as a whole.

    Isolated DC-DC Converters
  • Voltage - Output 3
    -
  • Voltage - Output 4
    -
  • Minimum Load Required
    -
  • Isolation Voltage

    Isolation voltage refers to a test of the ability of an insulator to minimize the flow of electric current with a high applied voltage.

    -
  • Product
    Isolated
  • Features
    Adjustable Output, IP20
  • Input Voltage
    +/- 9 VDC to +/- 16.8 VDC
  • Length
    2 mm
  • Width
    36mm
  • Height
    130mm
0 Similar Products Remaining