ARE13A4H

Panasonic Electric Works ARE13A4H

Part No:

ARE13A4H

Datasheet:

-

Package:

-

ROHS:

AINNX NO:

872797-ARE13A4H

Description:

PANASONIC ELECTRIC WORKS ARE13A4H RELAY, SPDT, 30VDC, 0.5A

Products specifications
  • Factory Lead Time
    12 Weeks
  • Mount
    Surface Mount
  • Mounting Type
    Surface Mount
  • Number of Pins
    9
  • Weight
    5g
  • CoilResistance
    101Ohm
  • Contact Materials
    Gold Plating
  • ElectricalLife
    300000 Cycle(s)
  • Isolation-Max
    30 dB
  • Operating Temperature

    The operating temperature is the range of ambient temperature within which a power supply, or any other electrical equipment, operate in. This ranges from a minimum operating temperature, to a peak or maximum operating temperature, outside which, the power supply may fail.

    -40°C~70°C
  • Packaging

    Semiconductor package is a carrier / shell used to contain and cover one or more semiconductor components or integrated circuits. The material of the shell can be metal, plastic, glass or ceramic.

    Tube
  • Series
    ARE
  • Published
    2004
  • Part Status

    Parts can have many statuses as they progress through the configuration, analysis, review, and approval stages.

    Not For New Designs
  • Moisture Sensitivity Level (MSL)
    4 (72 Hours)
  • Number of Terminations
    9
  • Termination
    Gull Wing
  • Additional Feature

    Any Feature, including a modified Existing Feature, that is not an Existing Feature.

    RELEASE TIME WITHOUT DIODE
  • HTS Code

    HTS (Harmonized Tariff Schedule) codes are product classification codes between 8-1 digits. The first six digits are an HS code, and the countries of import assign the subsequent digits to provide additional classification. U.S. HTS codes are 1 digits and are administered by the U.S. International Trade Commission.

    8536.41.00.20
  • Power Rating
    200mW
  • Depth
    11.2mm
  • Current Rating

    Current rating is the maximum current that a fuse will carry for an indefinite period without too much deterioration of the fuse element.

    500mA
  • Frequency
    2.6GHz
  • Termination Style
    Gull Wing
  • Contact Resistance
    100mOhm
  • Insulation Resistance

    The measurement of insulation resistance is carried out by means of a megohmmeter – high resistance range ohmmeter. A general rule-of-thumb is 10 Megohm or more.

    100000000Ohm
  • Contact Current(DC)-Max
    0.5A
  • Max Current Rating
    10mA
  • Impedance

    In electrical engineering, impedance is the opposition to alternating current presented by the combined effect of resistance and reactance in a circuit.

    75Ohm
  • Throw Configuration
    SPDT
  • Max Voltage Rating (DC)
    24V
  • Contact Form

    A page on a website that allows users to communicate with the site owner. The page has fields for filling in name, address and type of comment. On most company websites, email and mailing addresses are also included; however, the contact form provides an immediate, convenient way for users to ask the company questions.

    SPDT (1 Form C)
  • Relay Type
    RF
  • Operate Time

    The time interval between the instant of the occurrence of a specified input condition to a system and the instant of completion of a specified operation.

    10ms
  • Coil Voltage
    4.5VDC
  • Coil Type

    There are 2 different types of 'coil'; one has copper on it (IUD) and the other contains hormone (Mirena IUS). Both are over 99% effective at protecting against pregnancy.

    Non Latching
  • Switching Voltage

    The maximum switching voltage of a relay is the maximum voltage that can be across the contacts whether the relay is open or closed. Operating a relay with high voltages present can cause arcing, and this in turn erodes the contacts and eventually degrades contact performance.

    30VDC -Max
  • Coil Current

    A current coil is basically a coil, such as, a wire wrapped around an electrical conductor.

    44.4mA
  • Release Time

    In telecommunication, release time is the time interval for a circuit to respond when an enabling signal is discontinued

    5ms
  • Contact (DC) Max Rating R Load
    .5A@30VDC
  • Must Operate Voltage
    3.38VDC
  • Power Consumption

    Power consumption is the amount of input energy (measured in watts) required for an electrical appliance to function. This is opposed to power output which is a measure of the level of performance, of a heat pump for example.

    200mW
  • Must Release Voltage
    0.45VDC
  • Contact/Output Supply Type
    DC
  • Relay Action
    MOMENTARY
  • Coil Voltage (DC)
    4.5V
  • Coil/Input Supply Type
    DC
  • VSWR
    1.5
  • Insertion Loss (dB)
    0.5 dB
  • Input Power-Max (CW)
    10W
  • Input Switching Control Type
    Random
  • Dielectric Strength Between Coil and Contacts
    1000 Vrms
  • Switching Current
    1A
  • Test Voltage
    500V
  • Switching Time
    15 ms
  • Length
    20.2mm
  • REACH SVHC
    Unknown
  • Radiation Hardening

    Radiation hardening is the process of making electronic components and circuits resistant to damage or malfunction caused by high levels of ionizing radiation, especially for environments in outer space (especially beyond the low Earth orbit), around nuclear reactors and particle accelerators, or during nuclear accidents or nuclear warfare.

    No
  • RoHS Status

    RoHS means “Restriction of Certain Hazardous Substances” in the “Hazardous Substances Directive” in electrical and electronic equipment.

    RoHS Compliant
  • Lead Free
    Lead Free
0 Similar Products Remaining