E8F2-DN0C

Omron Automation and Safety E8F2-DN0C

Part No:

E8F2-DN0C

Package:

Module Box with Display

ROHS:

AINNX NO:

4730491-E8F2-DN0C

Description:

Industrial Pressure Sensors 0 to -14.6 psi Neg. Guage

Products specifications
  • Factory Lead Time
    44 Weeks
  • Mount
    Screw
  • Package / Case
    Module Box with Display
  • Voltage Rated

    RATED voltage is the voltage on the nameplate - the "design point" for maximum power throughput and safe thermal operation.

    24V
  • Operating Temperature

    The operating temperature is the range of ambient temperature within which a power supply, or any other electrical equipment, operate in. This ranges from a minimum operating temperature, to a peak or maximum operating temperature, outside which, the power supply may fail.

    0°C~55°C
  • Series
    E8F2
  • Published
    2000
  • Part Status

    Parts can have many statuses as they progress through the configuration, analysis, review, and approval stages.

    Active
  • Moisture Sensitivity Level (MSL)
    1 (Unlimited)
  • Termination
    Cable
  • Max Operating Temperature

    The Maximum Operating Temperature is the maximum body temperature at which the thermistor is designed to operate for extended periods of time with acceptable stability of its electrical characteristics.

    55°C
  • Min Operating Temperature
    0°C
  • Applications
    Industrial Automation
  • Voltage - Rated DC
    24V
  • Voltage - Supply
    12V~24V
  • Output
    1 V ~ 5 V
  • Termination Style
    Cable
  • Output Voltage
    5V
  • Output Type
    NPN - Open Collector
  • Operating Supply Voltage

    The voltage level by which an electrical system is designated and to which certain operating characteristics of the system are related.

    18V
  • Max Supply Voltage

    In general, the absolute maximum common-mode voltage is VEE-0.3V and VCC+0.3V, but for products without a protection element at the VCC side, voltages up to the absolute maximum rated supply voltage (i.e. VEE+36V) can be supplied, regardless of supply voltage.

    24V
  • Min Supply Voltage

    The minimum supply voltage (V min ) is explored for sequential logic circuits by statistically simulating the impact of within-die process variations and gate-dielectric soft breakdown on data retention and hold time.

    12V
  • Number of Ports

    A port is identified for each transport protocol and address combination by a 16-bit unsigned number,.

    2
  • Accuracy
    ±3%
  • Operating Pressure

    An operating pressure is the amount of internal force applied to the walls of some type of pressure vessel during normal conditions.

    -14.6PSI (-100.66kPa)
  • Pressure Type
    Vacuum
  • Port Style
    Threaded
  • Port Size
    Female -M5 Male - 1/8 3.18mm BSPT
  • Maximum Pressure
    -58PSI (-399.9kPa)
  • Max Pressure
    -58 PSI
  • Height
    28mm
  • Length
    28mm
  • Width
    46mm
  • REACH SVHC
    Unknown
  • RoHS Status

    RoHS means “Restriction of Certain Hazardous Substances” in the “Hazardous Substances Directive” in electrical and electronic equipment.

    RoHS Compliant
0 Similar Products Remaining