E2A-S08KN04-M5-C2

Omron Automation and Safety E2A-S08KN04-M5-C2

Part No:

E2A-S08KN04-M5-C2

Datasheet:

E2A Datasheet

Package:

Cylinder, Threaded - M8

ROHS:

AINNX NO:

2821705-E2A-S08KN04-M5-C2

Description:

SENSOR PROX INDUCTIVE 4MM CYLIND

Products specifications
  • Factory Lead Time
    15 Weeks
  • Mount
    Flush, Panel
  • Package / Case
    Cylinder, Threaded - M8
  • Number of Pins
    3
  • Housing Material
    Stainless Steel
  • Material - Body
    Stainless Steel
  • SwitchingFrequency
    1kHz
  • Operating Temperature

    The operating temperature is the range of ambient temperature within which a power supply, or any other electrical equipment, operate in. This ranges from a minimum operating temperature, to a peak or maximum operating temperature, outside which, the power supply may fail.

    -40°C~70°C
  • Series
    E2A
  • Published
    2001
  • Part Status

    Parts can have many statuses as they progress through the configuration, analysis, review, and approval stages.

    Active
  • Moisture Sensitivity Level (MSL)
    1 (Unlimited)
  • Termination
    Connector
  • Max Operating Temperature

    The Maximum Operating Temperature is the maximum body temperature at which the thermistor is designed to operate for extended periods of time with acceptable stability of its electrical characteristics.

    70°C
  • Min Operating Temperature
    -40°C
  • Voltage - Supply
    10V~32V
  • Shielding
    Unshielded
  • Ingress Protection

    Ingress Protection rating (or just IP rating), is an international standard (IEC 60529) used to rate the degree of protection or sealing effectiveness in electrical enclosures against intrusion of objects, water, dust or accidental contact. It corresponds to the European standard EN 60529.

    IP67, IP69K
  • Termination Style
    Connector
  • Output Type
    NPN-NC, 3-Wire
  • Operating Supply Voltage

    The voltage level by which an electrical system is designated and to which certain operating characteristics of the system are related.

    24V
  • Sensing Distance

    It is the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation. (Normally, it is 70 to 80 % of the maximum operation distance.)

    0.157 (4mm)
  • Sensor Type
    Inductive
  • Sensing Method
    Inductive
  • Indicator

    HTS (Harmonized Tariff Schedule) codes are product classification codes between 8-1 digits. The first six digits are an HS code, and the countries of import assign the subsequent digits to provide additional classification. U.S. HTS codes are 1 digits and are administered by the U.S. International Trade Commission.

    LED
  • Response Frequency

    In electronics, frequency response is the quantitative measure of the output spectrum of a system or device in response to a stimulus, and is used to characterize the dynamics of the system. It is a measure of magnitude and phase of the output as a function of frequency, in comparison to the input.

    1kHz
  • Switching Current
    200mA
  • Length
    27mm
  • RoHS Status

    RoHS means “Restriction of Certain Hazardous Substances” in the “Hazardous Substances Directive” in electrical and electronic equipment.

    RoHS Compliant
  • Ratings
    IP67
0 Similar Products Remaining