NJM3404AM-(TE1)

NJR CORPORATION NJM3404AM-(TE1)

Part No:

NJM3404AM-(TE1)

Manufacturer:

NJR CORPORATION

Datasheet:

-

Package:

0603 (1608 Metric)

AINNX NO:

46084038-NJM3404AM-(TE1)

Category:

Amplifiers

Description:

Single-Supply Dual Op Amp

Products specifications
  • Package / Case
    0603 (1608 Metric)
  • Surface Mount

    having leads that are designed to be soldered on the side of a circuit board that the body of the component is mounted on.

    YES
  • Number of Pins
    8
  • Supplier Device Package
    0603
  • Number of Terminals
    8
  • Package
    Tape & Reel (TR)
  • Base Product Number
    RN731J
  • Mfr
    KOA Speer Electronics, Inc.
  • Product Status
    Obsolete
  • RoHS
    Compliant
  • Package Description
    SOP,
  • Package Style
    SMALL OUTLINE
  • Package Body Material
    PLASTIC/EPOXY
  • Operating Temperature-Min
    -40 °C
  • Slew Rate-Nom
    1.2 V/us
  • Operating Temperature-Max
    85 °C
  • Manufacturer Part Number
    NJM3404AM-(TE1)
  • Supply Voltage-Nom (Vsup)
    15 V
  • Package Code
    SOP
  • Package Shape
    RECTANGULAR
  • Manufacturer
    New Japan Radio Co Ltd
  • Part Life Cycle Code
    Active
  • Ihs Manufacturer
    NEW JAPAN RADIO CO LTD
  • Common-mode Reject Ratio-Nom
    90 dB
  • Risk Rank
    5.6
  • Part Package Code
    SOIC
  • Neg Supply Voltage Limit-Max
    -18 V
  • Operating Temperature

    The operating temperature is the range of ambient temperature within which a power supply, or any other electrical equipment, operate in. This ranges from a minimum operating temperature, to a peak or maximum operating temperature, outside which, the power supply may fail.

    -55°C ~ 155°C
  • Series
    RN73
  • Size / Dimension
    0.063 L x 0.031 W (1.60mm x 0.80mm)
  • Tolerance
    ±0.05%
  • JESD-609 Code
    e6
  • Number of Terminations
    2
  • ECCN Code
    EAR99
  • Temperature Coefficient

    The resistance-change factor per degree Celsius of temperature change is called the temperature coefficient of resistance. This factor is represented by the Greek lower-case letter “alpha” (α). A positive coefficient for a material means that its resistance increases with an increase in temperature.

    ±25ppm/°C
  • Resistance
    7.96 kOhms
  • Terminal Finish
    TIN BISMUTH
  • Max Operating Temperature

    The Maximum Operating Temperature is the maximum body temperature at which the thermistor is designed to operate for extended periods of time with acceptable stability of its electrical characteristics.

    85 °C
  • Min Operating Temperature
    -40 °C
  • Composition
    Thin Film
  • Power (Watts)
    0.063W, 1/16W
  • HTS Code

    HTS (Harmonized Tariff Schedule) codes are product classification codes between 8-1 digits. The first six digits are an HS code, and the countries of import assign the subsequent digits to provide additional classification. U.S. HTS codes are 1 digits and are administered by the U.S. International Trade Commission.

    8542.33.00.01
  • Subcategory
    Operational Amplifier
  • Technology
    BIPOLAR
  • Terminal Position
    DUAL
  • Terminal Form

    Occurring at or forming the end of a series, succession, or the like; closing; concluding.

    GULL WING
  • Number of Functions
    2
  • Terminal Pitch

    The center distance from one pole to the next.

    1.27 mm
  • Reach Compliance Code
    compliant
  • Pin Count

    a count of all of the component leads (or pins)

    8
  • JESD-30 Code
    R-PDSO-G8
  • Qualification Status

    An indicator of formal certification of qualifications.

    Not Qualified
  • Operating Supply Voltage

    The voltage level by which an electrical system is designated and to which certain operating characteristics of the system are related.

    15 V
  • Temperature Grade

    Temperature grades represent a tire's resistance to heat and its ability to dissipate heat when tested under controlled laboratory test conditions.

    INDUSTRIAL
  • Number of Channels
    2
  • Nominal Supply Current

    Nominal current is the same as the rated current. It is the current drawn by the motor while delivering rated mechanical output at its shaft.

    3.5 mA
  • Output Current

    The rated output current is the maximum load current that a power supply can provide at a specified ambient temperature. A power supply can never provide more current that it's rated output current unless there is a fault, such as short circuit at the load.

    30 mA
  • Slew Rate

    the maximum rate of output voltage change per unit time.

    1.2 V/µs
  • Amplifier Type
    OPERATIONAL AMPLIFIER
  • Common Mode Rejection Ratio
    70 dB
  • Seated Height-Max
    2 mm
  • Input Offset Voltage (Vos)
    5 mV
  • Gain Bandwidth Product

    The gain–bandwidth product (designated as GBWP, GBW, GBP, or GB) for an amplifier is the product of the amplifier's bandwidth and the gain at which the bandwidth is measured.

    1.2 MHz
  • Neg Supply Voltage-Nom (Vsup)
    -15 V
  • Unity Gain BW-Nom
    1200 kHz
  • Voltage Gain
    100 dB
  • Average Bias Current-Max (IIB)
    0.2 µA
  • Supply Voltage Limit-Max
    18 V
  • Max Dual Supply Voltage

    A Dual power supply is a regular direct current power supply. It can provide a positive as well as negative voltage. It ensures stable power supply to the device as well as it helps to prevent system damage.

    18 V
  • Min Dual Supply Voltage
    2 V
  • Input Bias Current
    200 nA
  • Input Offset Voltage-Max
    5000 µV
  • Features
    Moisture Resistant
  • Height Seated (Max)
    0.022 (0.55mm)
  • Width
    5 mm
  • Length
    5 mm
0 Similar Products Remaining