PA-838-102G-VCR

Nidec Copal Electronics PA-838-102G-VCR

Part No:

PA-838-102G-VCR

Package:

Cylinder

ROHS:

AINNX NO:

4730487-PA-838-102G-VCR

Description:

PRESSURE TRANSDUCERS WITH AMP.

Products specifications
  • Factory Lead Time
    11 Weeks
  • Package / Case
    Cylinder
  • Operating Temperature

    The operating temperature is the range of ambient temperature within which a power supply, or any other electrical equipment, operate in. This ranges from a minimum operating temperature, to a peak or maximum operating temperature, outside which, the power supply may fail.

    -20°C~70°C
  • Series
    PA-838
  • Part Status

    Parts can have many statuses as they progress through the configuration, analysis, review, and approval stages.

    Active
  • Moisture Sensitivity Level (MSL)
    1 (Unlimited)
  • Applications
    Industrial Automation
  • Voltage - Supply
    24V
  • Output
    4 mA ~ 20 mA
  • Termination Style
    M12
  • Output Type
    Analog Current
  • Accuracy
    ±0.05%
  • Operating Pressure

    An operating pressure is the amount of internal force applied to the walls of some type of pressure vessel during normal conditions.

    14.23PSI (98.1kPa)
  • Pressure Type
    Gauge
  • Port Style
    Threaded
  • Maximum Pressure
    28.43PSI (196kPa)
  • Sensors/Transducers Type
    PRESSURE SENSOR,PEIZORESISTIVE
  • Features
    Temperature Compensated
  • RoHS Status

    RoHS means “Restriction of Certain Hazardous Substances” in the “Hazardous Substances Directive” in electrical and electronic equipment.

    ROHS3 Compliant
0 Similar Products Remaining
Documents & Media Download datasheets and manufacturer documentation for Nidec Copal Electronics PA-838-102G-VCR.